DOI 10.12200/j.issn.1003-0034.20221010
[Finite element analysis of the stability of Mason type Ⅲ radial head fracture fixed with three cross-bridge headless compression screw and locking plate].
Аннотация
OBJECTIVE
To compare the biomechanical stability of three cross-bridge headless compression screws and locking plates in the fixation of Mason type Ⅲ radial head fractures by finite element method.
METHODS
Using reverse modeling technology, the radial CT data and internal fixation data of a healthy 25-year-old male were imported into the relevant software. Three-dimensional finite element model of 3 cross-bridge headless compression screws and locking plates for MasonⅢ radial head fractures were established, and the radial head was loaded with 100 N axial loading. The maximum displacement, maximum Von Mises stress and stress distribution of the two groups were compared.
RESULTS
The maximum displacements of the three cross-bridge screws group and locking plate group were 0.069 mm and 0.087 mm respectively, and the Von Mises stress peaks were 18.59 MPa and 31.85 MPa respectively. The stress distribution of the three screws group was more uniform.
CONCLUSION
Both internal fixation methods can provide good fixation effect. CoMPared with the locking plate fixation method, the 3 cross-bridge headless compression screws fixation is more stable and the stress distribution is more uniform.