MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00330-024-11232-2

Медицинская библиотека · European radiology · 2024

Suppression of immobilisation device on wrist radiography to improve fracture visualisation.

Lee Sungwon, Chun Keum San, Lee Seungeun, Park Hyemin, Le Tuan Dinh, Jung Joon-Yong

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

This study validates the use of CycleGAN-generated wrist radiographs with digitally removed splints, specifically assessing their impact on fracture visualisation.

MATERIALS AND

METHODS

We retrospectively collected wrist radiographs from 1748 patients who had imaging before and after splint application at a single institution. The dataset was divided into training (1696 patients, 5353 images) and testing sets (52 patients, 965 images). A CycleGAN-based model was trained to generate splint-free wrist radiographs (generated "splint-less") from the original "splint" images. A pre-trained fracture detection model (YOLO8s) was used to assess fracture detection performance on three image groups: original "splint-less" radiographs, original "splint" radiographs, and generated "splint-less" radiographs. Two radiologists scored the generated images. Subtraction images quantified overall image alterations. Precision, recall, and F1 scores were used to compare fracture detection performance.

RESULTS

CycleGAN effectively generated splint-suppressed radiographs with minimal remaining splint density (< 10% remaining in 97.99%), hardware distortion (< 10% change in 100%), anatomical distortion (< 10% in 99.63%), and fracture lesion changes (< 10% change in 100%). New artefacts were rare (absent in 97.54%). Notably, the fracture detection model achieved higher precision (0.94 vs. 0.92), recall (0.63 vs. 0.5), and F1 score (0.75 vs. 0.65) on the generated "splint-less" radiographs compared to the original "splint" radiographs, approaching the performance on original "splint-less" radiographs (F1 0.71). Furthermore, greater image alterations by CycleGAN correlated with larger improvements in fracture detection.

CONCLUSION

CycleGAN successfully removed splint densities from wrist radiographs with splints.

KEY POINTS: Question Can CycleGAN (Generative Adversarial Networks), designed for image-to-image translation, generate synthetic "splint-less" radiographs to improve fracture visualisation in follow-up radiographs? Findings Removal of splint densities from wrist radiographs using Generative Adversarial Networks preserved anatomical structures and improved the performance of a fracture detection model. Clinical relevance Generated splint-less radiographs can enhance the performance of wrist fracture detection in wrist radiographs, benefiting both human clinicians and AI-powered diagnostic tools.

Для цитирования: Lee Sungwon, Chun Keum San, Lee Seungeun, Park Hyemin, Le Tuan Dinh, Jung Joon-Yong. Suppression of immobilisation device on wrist radiography to improve fracture visualisation.. European radiology. 2024. DOI: 10.1007/s00330-024-11232-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.