Prospective Comparative Evaluation of the Xpert MTB/RIF and Xpert MTB/RIF Ultra Assays for Detecting Mycobacterium tuberculosis and Rifampin Resistance in High-resource, Intermediate-burden Settings.
Аннотация
BACKGROUND
The Xpert MTB/RIF Ultra (Xpert Ultra) was introduced to enhance the sensitivity of tuberculosis detection, particularly in smear-negative cases, compared with its predecessor, Xpert MTB/RIF (Xpert). However, its performance in high-resource, intermediate-burden settings remains unassessed. We prospectively compared the diagnostic accuracy of Xpert Ultra and Xpert for detecting Mycobacterium tuberculosis (MTB) and rifampin resistance in Korea.
METHODS
In total, 309 respiratory specimens were analyzed using both assays. We used two reference standards: mycobacterial culture and a composite reference standard based on clinical diagnosis and treatment decisions. Diagnostic performance, including sensitivity, specificity, and agreement between the two assays, was assessed. Spiking experiments using 13 MTB isolates with known rpoB mutations were performed to evaluate rifampin resistance detection.
RESULTS
Xpert Ultra showed increased, albeit not significantly, sensitivity (73.7% vs. 65.8% with culture; 63.8% vs. 53.2% with the composite reference standard) over Xpert. Its specificity was comparable to that of Xpert; however, a few false-positive results were observed among trace- and very low-positives. Among six culture-negative but Xpert Ultra-positive cases, two were clinically diagnosed as tuberculosis. Of the 13 rpoB mutant strains, Xpert correctly detected all mutations in the rifampin resistance-determining region, whereas Xpert Ultra yielded indeterminate results for Q432P and Q429H/L430P/H445Q.
CONCLUSIONS
Xpert Ultra tends to have increased sensitivity; however, it shows potential diagnostic ambiguity associated with trace- or very low-positive results. These findings highlight the importance of clinical correlation, particularly in culture-negative cases. Indeterminate results in certain rpoB mutations require cautious interpretation.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.