MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00068-024-02448-4

Медицинская библиотека · European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2024

Efficacy of lysostaphin-coated titanium plates on implant-associated MRSA osteitis in minipigs.

Jaekel Carina, Windolf Ceylan D, Bieler Dan, Oezel Lisa, Seiler Lars F, Lakomek Felix N, Beyersdorf Christoph, Mertens Jann, Steuwe Andrea, Windolf Joachim, Grassmann Jan P

СтатьяПеревод в очереди

Аннотация

PURPOSE: The growing incidence of implant-associated infections (IAIs) caused by biofilm-forming Staphylococcus aureus in combination with an increasing resistance to antibiotics requires new therapeutic strategies. Lysostaphin has been shown to eliminate this biofilm. Own studies confirm the effectiveness in a murine model. The current study characterizes the effects of lysostaphin-coated plates in an IAI minipig model.

METHODS

The femur of 30 minipigs was stabilized with a five-hole plate, a bone defect was created, and in 20 cases methicillin-resistant Staphylococcus aureus was applied. Ten animals served as control group. After 14 days, local debridement, lavage, and plate exchange (seven-hole plate) were performed. Ten of the infected minipigs received an uncoated plate and 10 a lysostaphin-coated plate. On day 84, the minipigs were again lavaged, followed by euthanasia. Bacterial load was quantified by colony-forming units (CFU). Immunological response was determined by neutrophils, as well as interleukins. Fracture healing was assessed radiologically.

RESULTS

CFU showed significant difference between infected minipigs with an uncoated plate and minipigs with a lysostaphin-coated plate (p = 0.0411). The infection-related excessive callus formation and calcification was significantly greater in the infected animals with an uncoated plate than in animals with a lysostaphin-coated plate (p = 0.0164/p = 0.0033). The analysis of polymorphonuclear neutrophils and interleukins did not reveal any pioneering findings.

CONCLUSION

This study confirms the minipig model for examining IAI. Furthermore, coating of plates using lysostaphin could be a promising tool in the therapeutic strategies of IAI. Future studies should focus on coating technology of implants and on translation into a clinical model.

Для цитирования: Jaekel Carina, Windolf Ceylan D, Bieler Dan, Oezel Lisa, Seiler Lars F, Lakomek Felix N, Beyersdorf Christoph, Mertens Jann, Steuwe Andrea, Windolf Joachim, Grassmann Jan P. Efficacy of lysostaphin-coated titanium plates on implant-associated MRSA osteitis in minipigs.. European journal of trauma and emergency surgery : official publication of the European Trauma Society. 2024. DOI: 10.1007/s00068-024-02448-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.