PURPOSE: This study aims to introduce the "tripod" technique using cannulated compression screw and two anti-rotational K-wires for treatment of unstable scaphoid waist fracture nonunion, and to compare it with the single cannulated screw fixation technique in term of scaphoid union and surgical outcomes.

METHODS

It was a retrospective study. From January 2014 to March 2020, 103 consecutive patients with scaphoid waist fracture nonunion treated with the tripod fixation and bone grafting (n = 45) or with single cannulated compression screw and bone grafting (n = 58) were included. All the procedures were performed by the same hand surgery team, and autologous cortico-cancellous radius bone graft was used for bony reconstruction. The minimal follow-up period was 12 months. The union rate and the time to union, range of motion (ROM), grip strength, Visual Analogue Scale (VAS), Quick Disabilities of the Arm, Shoulder and Hand (DASH) score and modified Mayo Scores at the last visit were compared.

RESULTS

In tripod fixation group, bony union was achieved in all patients at the mean of 14.8 ± 3.8 weeks, while in the single cannulated screw fixation group the bony union rate was 94.8% (55/58) and the time to union was 17.6 ± 3.6 weeks. The difference of time to union was statistically significant (p = 0.027), but not for bony union rate (p = 0.122). At the last visit, no significant difference was found with respect to any clinical and radiographic outcome measures (all p > 0.05). The overall rate of complications was not significantly different between two groups (15.6% vs 10.3%, p = 0.430).

CONCLUSIONS

Tripod fixation technique with headless compression screw and two K-wires is a safe and effective technique for treatment of scaphoid nonunion fixation and can be considered to use in practice, especially for those potentially rotationally unstable cases.

Для цитирования: Zhang Xiaoran, Wang Li, Ma Xuelin, Wang Fengyu, Duan Wenxu, Shao Xinzhong. Cannulated compression screw with versus without two K-wire fixation for treatment of scaphoid waist fracture nonunion.. Journal of orthopaedic surgery and research. 2022. DOI: 10.1186/s13018-022-02975-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.