MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00198-012-2112-9

Медицинская библиотека · Osteoporosis international : a journal established as result of cooperation between the European Foundation for Osteoporosis and the National Osteoporosis Foundation of the USA · 2012

The effect of proton pump inhibitors on fracture risk: report from the Canadian Multicenter Osteoporosis Study.

Fraser L-A, Leslie W D, Targownik L E, Papaioannou A, Adachi J D, CaMos Research Group

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

UNLABELLED: A large Canadian cohort was studied over 10 years to see if proton pump inhibitor (PPI) use increased the risk of sustaining a fragility fracture. We found an increased risk of fracture in individuals who used PPIs. The risk remained after controlling for other known fracture risk factors.

INTRODUCTION

Multiple retrospective studies have linked proton pump inhibitor use with increased risk of fragility fracture. We prospectively studied the association between PPI use and fracture in a large cohort over a 10-year period while controlling for known fracture risk factors.

METHODS

We studied 9,423 participants in the Canadian Multicenter Osteoporosis Study. The cohort was formed in 1995-1997 and followed for 10 years with monitoring for incident nontraumatic fracture and PPI use. Cox regression analyses were used to assess the association between PPI use and incident fracture risk.

RESULTS

PPI use, coded as a time-dependent variable, was associated with a shorter time to first nontraumatic fracture, hazard ratio (HR)=1.75 (95% confidence interval (CI) 1.41-2.17, p<0.001). After controlling for multiple risk factors, including femoral neck bone density, the association remained significant, HR=1.40 (95% CI 1.11-1.77, p=0.004). Similar results were obtained after controlling for bisphosphonate use, using PPI "ever" use, or when the outcome was restricted to hip fracture.

CONCLUSIONS

In this large prospective population-based cohort study, we found an association between PPI use and increased risk of fragility fracture. Although the increased risk found was modest, this finding is important, given the high prevalence of PPI use and the excess morbidity and mortality associated with osteoporosis-related fractures.

Для цитирования: Fraser L-A, Leslie W D, Targownik L E, Papaioannou A, Adachi J D, CaMos Research Group. The effect of proton pump inhibitors on fracture risk: report from the Canadian Multicenter Osteoporosis Study.. Osteoporosis international : a journal established as result of cooperation between the European Foundation for Osteoporosis and the National Osteoporosis Foundation of the USA. 2012. DOI: 10.1007/s00198-012-2112-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.