MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1302/0301-620x.91b7.21914

Медицинская библиотека · The Journal of bone and joint surgery. British volume · 2009

The incidence of physiological radiolucency following Oxford unicompartmental knee replacement and its relationship to outcome.

Gulati A, Chau R, Pandit H G, Gray H, Price A J, Dodd C A F, Murray D W

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Narrow, well-defined radiolucent lines commonly observed at the bone-implant interface of unicompartmental knee replacement tibial components have been referred to as physiological radiolucencies. These should be distinguished from pathological radiolucencies, which are poorly defined, wide and progressive, and associated with loosening and infection. We studied the incidence and clinical significance of tibial radiolucent lines in 161 Oxford unicondylar knee replacements five years after surgery. All the radiographs were aligned with fluoroscopic control to obtain views parallel to the tibial tray to reveal the tibial bone-implant interface. We found that 49 knees (30%) had complete, 52 (32%) had partial and 60 (37%) had no radiolucent lines. There was no relationship between the incidence of radiolucent lines and patient factors such as gender, body mass index and activity, or operative factors including the status of the anterior cruciate ligament and residual varus deformity. Nor was any statistical relationship established between the presence of radiolucent lines and clinical outcome, particularly pain, assessed by the Oxford Knee score and the American Knee Society score. We conclude that radiolucent lines are common after Oxford unicompartmental knee replacement but that their aetiology remains unclear. Radiolucent lines were not a source of adverse symptoms or pain. Therefore, when attempting to identify a source of postoperative pain after Oxford unicompartmental knee replacement the presence of a physiological radiolucency should be ignored.

Для цитирования: Gulati A, Chau R, Pandit H G, Gray H, Price A J, Dodd C A F, Murray D W. The incidence of physiological radiolucency following Oxford unicompartmental knee replacement and its relationship to outcome.. The Journal of bone and joint surgery. British volume. 2009. DOI: 10.1302/0301-620x.91b7.21914.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.