MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00068-023-02400-y

Медицинская библиотека · European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2024

Does plate position influence the outcome in midshaft clavicular fractures? A multicenter analysis.

Buenter Isabelle Ruth, Kremo Valerie, Beeres Frank Johannes Paulus, van Veelen Nicole Maria, Galliker Beat, Link Bjoern-Christian, Babst Reto, Pape Hans-Christoph, van de Wall Bryan Joost Marinus

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

PURPOSE: To date, it remains unclear whether superior or anterior plating is the best option for treating midshaft clavicular fractures. The aim of this study was to compare both techniques with regard to the incidence of implant removal due to implant irritation, risk of complications, time to union, and function.

METHODS

In this retrospective cohort study, all midshaft clavicular fractures treated operatively between 2017 and 2020 in two hospitals in Switzerland were analyzed. The participating hospitals differed with regard to their standard practice; one offered superior plating only, while the other predominantly employed an anterior plate. The primary outcome was the incidence of implant removal for irritation. Secondary outcomes were time to union, complications, re-interventions, and range of motion during the follow-up period of at least 6 months.

RESULTS

In total, 168 patients were included in the study of which 81 (48%) received anterior plating and 87 (52%) superior plating. The overall mean age was 45 years (SD 16). There was no significant difference between anterior and superior plating with regard to implant removal (58.5% versus 57.1%, p = 0.887), infection (5.7% versus 1.8%, p = 0.071), and time to union (median 48 weeks versus 52 weeks, p = 0.643). Data on range of motion were available in 71 patients. There was no significant difference in anteflexion (median 180 degrees anterior versus 180 degrees superior) and abduction (median 180 degrees anterior versus 180 degrees superior) between the two groups.

CONCLUSION

This retrospective cohort study did not find sufficient evidence to recommend one implant position over the other for midshaft clavicular fractures with regard to removal due to irritation. Time to union was similar and Infections were equally rare in both groups. Notably, a considerable number of patients in both groups had their implants removed due to irritation. Larger prospective studies are needed to determine how much plate position contributes to the occurrence of irritation and whether other patient or implant-related factors might play a role. Until this is clarified, implant position should be based on surgeons preference and experience.

Для цитирования: Buenter Isabelle Ruth, Kremo Valerie, Beeres Frank Johannes Paulus, van Veelen Nicole Maria, Galliker Beat, Link Bjoern-Christian, Babst Reto, Pape Hans-Christoph, van de Wall Bryan Joost Marinus. Does plate position influence the outcome in midshaft clavicular fractures? A multicenter analysis.. European journal of trauma and emergency surgery : official publication of the European Trauma Society. 2024. DOI: 10.1007/s00068-023-02400-y.