MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00590-022-03203-4

Медицинская библиотека · European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2022

Modified use of the proximal humeral internal locking system (PHILOS) plate for distal femoral nonunions.

Poelmann Josje, Kloen Peter

СтатьяПеревод в очереди

Аннотация

PURPOSE: Nonunion is a common complication after a distal femoral fracture (DFF). Standard treatment consists of revision plating and/or bone grafting. Single lateral plating for a distal femoral nonunion can be insufficient in case of a persistent medial gap and compromised bone stock. Alternatively, dual plating can be used to treat a distal femoral nonunion, but to date there is no Gold standard. The aim of our study was to report our results after use of a minimally invasively placed proximal humeral internal locking system (Philos) plate as a medial buttress in the treatment of a distal femoral nonunion.

METHODS

Fifteen adult patients with a distal femoral nonunion were prospectively entered in a trauma database and retrospectively assessed. All patients underwent a similar operation, which included removal of failed hardware, nonunion debridement, fixation with a lateral plate, and a medial Philos plate combined with bone grafting. Data collected included union rate, time to union, complications and functional outcome.

RESULTS

In twelve out of fifteen patients (80%), the fracture united after our index operation. Median time to union was 4.8 months (range 1.6-15). Three patients (20%) needed additional bone grafting surgery. One patient underwent a Judet quadricepsplasty.

CONCLUSION

This study suggests that the Philos plate is a safe and effective adjunct as a medial buttress plate for distal femoral nonunions.

Для цитирования: Poelmann Josje, Kloen Peter. Modified use of the proximal humeral internal locking system (PHILOS) plate for distal femoral nonunions.. European journal of orthopaedic surgery & traumatology : orthopedie traumatologie. 2022. DOI: 10.1007/s00590-022-03203-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.