MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jvs.2013.10.076

Медицинская библиотека · Journal of vascular surgery · 2014

Digital obstructive arterial disease can be detected by laser Doppler measurements with high sensitivity and specificity.

Mahe Guillaume, Liedl David A, McCarter Charlene, Shepherd Roger, Gloviczki Peter, McPhail Ian R, Rooke Thom W, Wennberg Paul W

Сравнительное исследованиеОценочное исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVE

This study was conducted to determine the sensitivity and specificity of laser Doppler flowmetry (LDF) measurements for digital obstructive arterial disease (DOAD) using angiography as the reference standard and to compare the accuracy of different classical tests used to assess DOAD. Diagnosis of vascular abnormalities at the digital level is challenging. Angiography is the gold standard for assessment of DOAD but is invasive and expensive to perform.

METHODS

We performed a retrospective analysis of consecutive patients referred at Mayo Clinic (Rochester, Minn) for upper extremity arterial assessment during a 27-month period. Finger-brachial index, skin blood flow (in arbitrary units [a.u.]), and skin temperature (in degrees Celsius) were recorded in each digit on the pulp at baseline and after a thermal challenge test (hand placed in a thermal box at 47.0°C for 15 minutes). Angiogram analysis was blinded and performed by a radiologist using a vascularization scale ranging from 0 (no vessel) to 4 (normal). The receiver operating characteristic curve was used to define a specific cutoff point to detect DOAD. Twenty-two patients had LDF measurements and complete angiograms.

RESULTS

A total of 185 digits were analyzed because some patients had only analysis of one hand. The best area under the curve (AUC) was 0.98 (range, 0.94-0.99) for postwarming skin blood flow, with a cutoff point of ≤206 a.u. This AUC was statistically different from AUCs of all the other tests (P < .01). Sensitivity and specificity were 93% (95% confidence interval, 85%-97%) and 96% (95% confidence interval, 90%-99%), respectively.

CONCLUSIONS

LDF combined with a thermal challenge is highly accurate, safe, and noninvasive means to detect DOAD.

Для цитирования: Mahe Guillaume, Liedl David A, McCarter Charlene, Shepherd Roger, Gloviczki Peter, McPhail Ian R, Rooke Thom W, Wennberg Paul W. Digital obstructive arterial disease can be detected by laser Doppler measurements with high sensitivity and specificity.. Journal of vascular surgery. 2014. DOI: 10.1016/j.jvs.2013.10.076.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.