BACKGROUND

Dorsal root ganglion stimulation (DRGS) is an established method for treating persistent and severe pain conditions. However, performing DRGS has significant challenges. Current DRGS systems are expensive, hindering accessibility for many patients and health care systems. Additionally, placing DRGS devices requires specialized training in epidural techniques and lead anchoring methods. Technical and financial requirements also limit the clinical applicability and availability of DRGS.

OBJECTIVES

This study evaluated the feasibility of a new method for rapidly delivering near- DRG stimulation in human cadavers. The method involves a fluoroscopy-guided transforaminal approach using a fully implantable, injectable electrode, and its associated delivery system.

STUDY

DESIGN

A human cadaver feasibility study.

SETTING

A cadaver laboratory.

METHODS

In this study, 3 anesthesiologist pain physicians received training on the injectable electrode device and delivery system using spine phantom models. They then applied the device's associated implantation techniques to 2 adult male cadavers. In the first cadaver, a single injectable electrode was placed near the left L2 lumbar DRG. In the second cadaver, injectable electrodes were placed near the left L1 and L2 DRG levels, and a benchmark DRGS device was installed at the left L1 level using fluoroscopic guidance. A careful anatomical dissection was then performed for each implanted device.

RESULTS

The stimulating contacts of the injectable electrodes were accurately positioned within one mm of the DRG at the lumbar L1 and L2 levels in both cadavers. The distances of both the injectable lead and benchmark DRGS device at the L1 level were measured as one mm from the posterior aspect of the DRG.

LIMITATIONS: The findings of this study are based on anatomical examinations of a limited number of human cadavers and may not fully represent living human anatomy.

CONCLUSIONS

To our knowledge, this feasibility cadaver study is the first of its kind to examine the accuracy and efficiency of a fluoroscopy-guided transforaminal approach to place injectable electrodes near the DRG. These promising results suggest that this method could be a viable alternative to existing DRGS techniques, warranting further investigation into its clinical potential.

Для цитирования: Billet Bart, Jessen Christian, Moriggl Bernhard, Liu Derrick, Szabo Emily, Nieuwoudt Stephan, Abd-Elsayed Alaa, Soin Amol, Bendtsen Thomas Fichtner. Novel Injectable Nerve Stimulation Electrode Placed on the Dorsal Root Ganglion Using an Extravertebral Approach: A Feasibility Study in Cadavers.. Pain physician. 2024.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.