MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s001670050096

Медицинская библиотека · Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 1998

Arthroscopic and open shoulder stabilization using absorbable implants. A clinical and radiographic comparison of two methods.

Kartus J, Ejerhed L, Funck E, Köhler K, Sernert N, Karlsson J

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

The aim of this study was to compare the clinical and radiographic results in patients with recurrent unidirectional, post-traumatic shoulder instability (dislocations/subluxations). All the patients had a Bankart lesion and underwent reconstruction using either an open or an arthroscopic technique and absorbable implants. Thirty-three consecutive patients (36 shoulders) were operated on by one surgeon. Group A comprised 18 shoulders which underwent an open Bankart reconstruction using absorbable 3.7-mm TAG suture anchors. Group B comprised 18 shoulders which underwent a combination of an intra- and extra-articular arthroscopic stabilization using 8-mm Suretac fixators. The median number of dislocations before the reconstruction was 5(0-45) in group A and 4 (0-30) in group B (NS). The follow-up examination was performed by an independent observer after a median of 31 (range 25-38) months in group A and 28 (range 18-46) months in group B (NS). An independent radiologist without any knowledge of the surgical procedure evaluated all the radiographs. There were no re-dislocations in either group. In group A, the Rowe and Constant scores were 86 (range 61-98) and 89 (range 73-99), respectively. The corresponding values in group B were 92 (range 83-98; P = 0.05) and 96 (range 75-100; NS). The external rotation in abduction was 65 degrees (range 20 degrees-90 degrees) in group A and 83 degrees (range 65 degrees-105 degrees) in group B (P = 0.0017). The radiographs revealed that 10/18 (56%) in group A and 4/18 (23%) in group B had visible drill-holes or cystic formations in conjunction with the drill-holes (P = 0.002). In this study the open procedure resulted in a restriction in external rotation more frequently than the arthroscopic procedure. The radiographs revealed visible drill-holes or cystic formations in conjunction with the drill-holes more frequently when TAG suture anchors were used than when Suretac fixators were used. The radiographic changes did, not appear to affect the clinical outcome, however.

Для цитирования: Kartus J, Ejerhed L, Funck E, Köhler K, Sernert N, Karlsson J. Arthroscopic and open shoulder stabilization using absorbable implants. A clinical and radiographic comparison of two methods.. Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA. 1998. DOI: 10.1007/s001670050096.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.