Association of Bone Quality Measured by Noncontrast Computed Tomography Scan and Three-dimensional Computed Tomography-based Fracture Pattern in Intertrochanteric Femur Fracture in Adults.

Gupta Govind Kumar, Kullu Saumya, Guria Abhishek, Gourab Kumar, Rani Sudha

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Understanding intertrochanteric (IT) femur fractures, their causes, classifications, and the role of bone quality is crucial for management. Poor bone quality associated with osteoporosis increases fracture risk and poorer outcomes. While dual-energy X-ray absorptiometry is the gold standard, Hounsfield units (HUs) derived from computed tomography (CT) scans are a valuable, noninvasive alternative for assessing bone quality.

AIM AND

OBJECTIVES

To determine the association of bone quality, measured by noncontrast CT scan, with three-dimensional CT (3D-CT)-based fracture patterns in IT femur fractures in adults.

MATERIALS AND

METHODS

Over a period of 18 months, 137 patients with IT femoral fractures were included. Fracture classification using Evans (1949), Boyd and Griffin (1956), and Arbeitsgemeinschaft für Osteosynthesefragen/Orthopaedic Trauma Association (AO/OTA) (2018) was done. Bone quality was assessed by calculating the HU value from the largest spherical region of interest in the IT region of the unaffected side. 3D-CT-based classification system by Dr. R. B. Kalia and Dr. Shobha S. Arora was used.

RESULTS

The mean age was 65.4 ± 10.2 years, with females comprising 59.9%. AO/OTA type 31A2.2 was the most common, indicating frequent unstable fractures. Patients with stable fractures had significantly higher mean HU values (130.2 ± 22.1) compared to those with unstable fractures (105.4 ± 24.3) ( P < 0.001). A significant correlation ( P < 0.001) between the AO/OTA (2018) classification and the CT-based classification is evident.

CONCLUSION

Lower HU values, indicating poorer bone quality, are strongly associated with unstable fracture patterns. The significant correlation between CT-based assessments and AO/OTA classification validates the utility of advanced imaging techniques in assessing bone strength and fracture risk.

Для цитирования: Gupta Govind Kumar, Kullu Saumya, Guria Abhishek, Gourab Kumar, Rani Sudha. Association of Bone Quality Measured by Noncontrast Computed Tomography Scan and Three-dimensional Computed Tomography-based Fracture Pattern in Intertrochanteric Femur Fracture in Adults.. Annals of African medicine. 2025. DOI: 10.4103/aam.aam_284_25.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.