MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/s-0039-3400479

Медицинская библиотека · The International journal of angiology : official publication of the International College of Angiology, Inc · 2019

Left Atrial to Femoral Artery Full Cardiopulmonary Bypass: A Novel Technique for Descending and Thoracoabdominal Aortic Surgery.

Papanikolaou Dimitra, Savio Chris, Zafar Mohammad A, Freudzon Leon, Wu Jinlin, Abdelbaky Mohamed, Pelletier Keith J, Buntin Joelle, Faggion Vinholo Thais, Ziganshin Bulat A, Schwartz Brian, Elefteriades John A

СтатьяПеревод пока не подготовлен

Аннотация

Left atrial-femoral artery (LA-FA) bypass with a centrifugal pump and no oxygenator is commonly used for descending and thoracoabdominal aortic (DTAA) operations, mitigating the deleterious effects of cross-clamping. We present our initial experience performing DTAA replacement under LA-FA (left-to-left) cardiopulmonary bypass (CPB) with an oxygenator. DTAA replacement under LA-FA bypass with an oxygenator was performed in 14 consecutive patients (CPB group). The pulmonary vein and femoral artery (or distal aorta) were cannulated and the full CPB machine were used, including oxygenator, roller pump, pump suckers, and kinetically enhanced drainage. The CPB group was compared with 50 consecutive patients who underwent DTAA replacement utilizing traditional LA-FA bypass without an oxygenator (LA-FA group). Perioperative data were collected and statistical analyses were performed. All CPB patients maintained superb cardiopulmonary stability. The pump sucker permitted immediate salvage and return of shed blood. Superb oxygenation was maintained at all times. High-dose full CPB heparin was reversed without difficulty. The CPB group required markedly fewer blood transfusions than the LA-FA group (2.21 vs. 5.88 units, p  < 0.004). The 30-day mortality rate was 7.1% ( n  = 1) and there were no paraplegia cases in the CPB group versus 7 (14%) deaths and 3 (6%) paraplegia cases in the LA-FA group. Traditional LA-FA bypass without an oxygenator avoids high-dose heparin. In the present era, heparin reversal is more secure. Our experience finds that the novel application of LA-FA CPB with an oxygenator is safe and suggests improved hemodynamics (immediate return of shed blood) and a hemostatic advantage (avoidance of loss of coagulation factors in the cell saver).

Для цитирования: Papanikolaou Dimitra, Savio Chris, Zafar Mohammad A, Freudzon Leon, Wu Jinlin, Abdelbaky Mohamed, Pelletier Keith J, Buntin Joelle, Faggion Vinholo Thais, Ziganshin Bulat A, Schwartz Brian, Elefteriades John A. Left Atrial to Femoral Artery Full Cardiopulmonary Bypass: A Novel Technique for Descending and Thoracoabdominal Aortic Surgery.. The International journal of angiology : official publication of the International College of Angiology, Inc. 2019. DOI: 10.1055/s-0039-3400479.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.