MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/ijerph18010075

Медицинская библиотека · International journal of environmental research and public health · 2020

The Acute Effect of Foam Rolling on Eccentrically-Induced Muscle Damage.

Nakamura Masatoshi, Yasaka Koki, Kiyono Ryosuke, Onuma Remi, Yahata Kaoru, Sato Shigeru, Konrad Andreas

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Previous studies have shown significant improvement in muscle soreness and muscle function loss after 300-s foam rolling intervention two days after intense exercise. However, this duration is assumed to be too long, so investigating the effect of short-term duration foam rolling intervention on an eccentrically-damaged muscle is needed. This study aimed to eccentrically induce muscle damage in the leg extensors, and to detect the acute effect of 90-s foam rolling on muscle soreness and muscle function of the quadriceps muscle. We enrolled 17 healthy and nonathlete male volunteers. They performed a bout of eccentric exercise of the knee extensors with the dominant leg and received 90-s foam rolling intervention of the quadriceps two days after the eccentric exercise. The dependent variables were measured before the eccentric exercise (baseline), and before (preintervention) and after foam rolling intervention (postintervention), two days after the eccentric exercise. The results show that the preintervention muscle soreness and muscle strength values were significantly increased, compared with the baseline values, whereas the postintervention values were significantly decreased, compared with the preintervention values. Furthermore, 90-s of foam rolling intervention could improve muscle soreness and muscle function loss.

Для цитирования: Nakamura Masatoshi, Yasaka Koki, Kiyono Ryosuke, Onuma Remi, Yahata Kaoru, Sato Shigeru, Konrad Andreas. The Acute Effect of Foam Rolling on Eccentrically-Induced Muscle Damage.. International journal of environmental research and public health. 2020. DOI: 10.3390/ijerph18010075.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.