Respiratory-induced liver motion prediction using ECG as surrogate signal.

Cordón-Avila Ana, Stienstra Lobke, Wang Ying, Bhagavatula Sharath, Moreira Pedro Lopes Da Frota, Abayazid Momen

СтатьяПеревод в очереди

Аннотация

PURPOSE: This study investigates the use of electrocardiogram (ECG) as a surrogate signal to model the liver's respiratory-induced motion.

METHODS

A learning-based model was trained to predict respiratory-induced liver motion by relying exclusively on ECG data, without requiring additional imaging. A correspondence model based on an encoder-decoder architecture was defined to map internal liver motion from ECG signals. Experimental validation was conducted through a human subject study involving eight participants performing various breathing patterns.

RESULTS

The mean absolute error during normal breathing was 2.83 mm, while the overall error considering all breathing patterns was 4.02 mm with correlation coefficients above 0.90. More than 90% of predictions fell within reported acceptable error margins for needle insertion procedures. The model's performance reduces when the liver motion increases during deep breathing patterns.

CONCLUSION

ECG can serve as a reliable noninvasive surrogate for predicting liver motion. This approach offers the advantage of being readily available in clinical settings and can provide accurate guidance for interventional procedures.

Для цитирования: Cordón-Avila Ana, Stienstra Lobke, Wang Ying, Bhagavatula Sharath, Moreira Pedro Lopes Da Frota, Abayazid Momen. Respiratory-induced liver motion prediction using ECG as surrogate signal.. International journal of computer assisted radiology and surgery. 2026. DOI: 10.1007/s11548-026-03773-2.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.