MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11547-019-01063-3

Медицинская библиотека · La Radiologia medica · 2019

Receiver operating characteristic analysis of ultrasound joint inflammation in relation to structural damage and disease activity in rheumatoid arthritis.

Li HuiHua, Allen John Carson, Thumboo Julian, Tan York Kiat

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To investigate whether ultrasound greyscale (GS) and power Doppler (PD) joint inflammation may be useful in identifying rheumatoid arthritis (RA) patients in different states of structural damage and disease activity.

METHODS

In this cross-sectional study utilizing 36-joint ultrasonography, bone erosion was scored dichotomously (1 = yes/0 = no) while GS and PD joint inflammations were graded semi-quantitatively (0-3) at each joint recess. Sensitivity, specificity and receiver operating characteristic (ROC) curve analysis was applied to study ultrasound joint inflammation as a clinical marker for identifying patients with erosion score > 4.5 (median) and DAS28 > 2.6, > 3.2 and > 5.1, respectively.

RESULTS

1080 joints and 1800 joint recesses were scanned in 30 RA patients (mean disease duration, 70.3 months). Patients with GS score > 35.5 (median) had significantly higher ultrasound erosion scores when compared to those with GS score ≤ 35.5 (mean (95% CI) ultrasound erosion scores, 9.27 (6.12-12.4) versus 3.33 (2.31-4.36), respectively. p = 0.0027). Patients with PD positivity had significantly higher DAS28 scores compared to those with PD negativity (mean (95% CI) DAS28, 3.84 (3.35, 4.34) versus 2.86 (2.18, 3.54), respectively. p = 0.0457). Area under the ROC curve (AUC) based on cut-off GS scores ≥ 38 to identify patients with ultrasound erosion score >4.5 was 0.82 (sensitivity = 73.3%, specificity = 86.7%, accuracy = 80%). AUC based on cut-off PD scores ≥ 2.5 for identifying patients with DAS28 > 5.1 was 0.88 (sensitivity = 100%, specificity = 69.2%, accuracy = 73.3%).

CONCLUSIONS

Ultrasound GS and PD joint inflammation scores can be useful in identifying RA patients with high bone erosion burden (ultrasound erosion score > 4.5) and high disease activity (DAS28 > 5.1), respectively.

Для цитирования: Li HuiHua, Allen John Carson, Thumboo Julian, Tan York Kiat. Receiver operating characteristic analysis of ultrasound joint inflammation in relation to structural damage and disease activity in rheumatoid arthritis.. La Radiologia medica. 2019. DOI: 10.1007/s11547-019-01063-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.