BACKGROUND

Multiple techniques are commonly used for posterior cruciate ligament (PCL) reconstruction. However, the optimum method regarding the fixation of PCL reconstruction after PCL tears remains debatable. The purpose of this study was to compare the biomechanical properties among three different tibial fixation procedures for transtibial single-bundle PCL reconstruction.

METHODS

Thirty-six porcine tibias and porcine extensor tendons were randomized into three fixation study groups: the interference screw fixation (IS) group, the transtibial tubercle fixation (TTF) group, and TTF + IS group (n = 12 in each group). The structural properties of the three fixation groups were tested under cyclic loading and load-to-failure. The slippage after the cyclic loading test and the stiffness and ultimate failure load after load-to-failure testing were recorded.

RESULTS

After 1000 cycles of cyclic testing, no significant difference was observed in graft slippage among the three groups. For load-to-failure testing, the TTF + IS group showed a higher ultimate failure load than the TTF group and the IS group (876.34 ± 58.78 N vs. 660.92 ± 77.74 N [P < 0.001] vs. 556.49 ± 65.33 N [P < 0.001]). The stiffness in the TTF group was significantly lower than that in the IS group and the TTF + IS group (92.77 ± 20.16 N/mm in the TTF group vs. 120.27 ± 15.66 N/m in the IS group [P = 0.001] and 131.79 ± 17.95 N/mm in the TTF + IS group [P < 0.001]). No significant difference in the mean stiffness was found between the IS group and the TTF + IS group (P = 0.127).

CONCLUSIONS

In this biomechanical study, supplementary fixation with transtibial tubercle sutures increased the ultimate failure load during load-to-failure testing for PCL reconstruction.

Для цитирования: Duan Ming-Yi, Sun Rui, Zhuang Lei-Ting, Zhang Hang-Zhou. Biomechanical evaluation of a novel transtibial posterior cruciate ligament reconstruction using high-strength sutures in a porcine bone model.. Chinese medical journal. 2021. DOI: 10.1097/cm9.0000000000001725.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.