The usefulness of computer-aided joint space analysis in the assessment of rheumatoid arthritis.

Pfeil Alexander, Renz Diane M, Hansch Andreas, Kainberger Franz, Lehmann Gabriele, Malich Ansgar, Wolf Gunter, Böttcher Joachim

Оценочное исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVE

Computer-aided joint space analysis (CAJSA) is a newly developed technique for the measurement of radiogeometrically detectable joint space widths of the metacarpal-phalangeal (JSD-MCP) and proximal-interphalangeal articulations (JSD-PIP). The aim of this study was to verify the sensitivity and specificity of these CAJSA measurements in the assessment of established RA.

METHODS

Four hundred and fifty-eight participants (248 healthy subjects, 210 RA patients) underwent computerized semi-automated measurements of the JSD-MCP and JSD-PIP articulations (CAJSA, Radiogrammetry Kit, Version 1.3.6) based on digitally performed radiographs. The Sharp joint space narrowing score was also performed to determine RA-related joint space narrowing.

RESULTS

The significant severity-dependent reduction for JSD-MCP was -44.0% and for JSD-PIP, -25.94% between Sharp scores 0 and 3. The sensitivity and specificity of JSD-MCP (total) was 88.1% versus 77.8%, respectively (AUC = 0.920; P < 0.001). Furthermore, JSD-PIP (total) revealed a lower sensitivity and specificity with 61.4% and 88.7% (AUC = 0.878; P < 0.001).

CONCLUSION

The CAJSA method presented a reliable assessment of disease-related joint space narrowing in patients suffering from RA with excellent sensitivity and specificity. By providing quantitative data, other scoring methods could be significantly improved, and thereby the accuracy of the diagnosis and a better therapeutic evaluation could be achieved.

Для цитирования: Pfeil Alexander, Renz Diane M, Hansch Andreas, Kainberger Franz, Lehmann Gabriele, Malich Ansgar, Wolf Gunter, Böttcher Joachim. The usefulness of computer-aided joint space analysis in the assessment of rheumatoid arthritis.. Joint bone spine. 2012. DOI: 10.1016/j.jbspin.2012.10.022.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.