Background

The purpose of this retrospective study was to report outcomes of arthroscopic bone grafting and K-wire fixation to treat scaphoid non-union.

Methods

We included in at two healthcare facilities, 42 consecutive patients (34 men, 8 women) with a mean age of 25 years (range 15-56 years) with scaphoid non-union of the proximal and middle third without intracarpal deformity or SNAC osteoarthritis. All patients were evaluated (pain, range of motion, strength, function, X-rays) by an independent examiner.

Results

At the mean follow-up of 18 months (range 12-56), pain was significantly reduced from 7 to 1 on a visual analogue scale (out of 10). The scores on the Quick Disabilities of the Arm, Shoulder and Hand questionnaire and Patient Rated Wrist Evaluation were improved significantly. At the last review, grip strength was 83% of the contralateral side, the average wrist flexion-extension was 125° and the radioulnar deviation was 58°. Bone union was achieved in 37 cases (88%). The mean time of checking the bone union was 3 months (range, 2-8). Four patients required revision surgery because of failed union.

Conclusions

Based on our findings, we found that this procedure can be used as a surgical treatment for scaphoid non-union of the proximal and middle third without intracarpal deformity or osteoarthritis. The arthroscopic bone grafting is a reliable, effective, and minimally invasive procedure.

Для цитирования: Lamon Bérangère, Ardouin Ludovic, Bellemère Philippe, Dautel Gilles, Athlani Lionel. Arthroscopic Bone Grafting for Scaphoid Nonunion: A Retrospective Study of 42 Cases.. The journal of hand surgery Asian-Pacific volume. 2021. DOI: 10.1142/s242483552150051x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.