MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-023-48791-1

Медицинская библиотека · Scientific reports · 2023

Effect of screw angulation on the bending performance of polyaxial locking interfaces: a micro-CT evaluation.

Glowacki Jakub, Bartkowiak Tomasz, Paczos Piotr, Gapinski Bartosz, Mietlinski Patryk, Zawadzki Pawel, Weiss Weronika, Lapaj Lukasz

СтатьяПеревод в очереди

Аннотация

Polyaxial locking plates rely on a specific thread-to-thread interface of the screw head and the plate hole. The objective of this study was to evaluate the mechanical performance of single screw interfaces when inserted off-axis and to establish correlations between those parameters and the engagement of the screw head and the plate hole thread. Three polyaxial locking screw systems were inserted into the corresponding plates at various angles (0°, 5°, 10°, and 15° off-axis). The screws were tested until failure. A micro-CT was performed to examine the interface between the plate hole and the screw head. The standard insertion at 0° sustained the greatest maximum bending strength without relocation in the screw hole. Screws inserted at 15° showed a significant reduction in force of up to 44%, 55% and 57%, respectively. Micro-CT analysis of the interface showed a significant loss of thread engagement for off-axis insertion. Polyaxial plates offer additional advantages for off-axis placement of screws. However, this flexibility is related to a significant decrease in both thread engagement and bending strength compared to monoaxial insertion. Regardless the insertion angle, the loss of stability is comparable when screws are placed off-axis. Surgeons are advised to consider off-axis insertion as a salvage option, providing access to better bone stock.

Для цитирования: Glowacki Jakub, Bartkowiak Tomasz, Paczos Piotr, Gapinski Bartosz, Mietlinski Patryk, Zawadzki Pawel, Weiss Weronika, Lapaj Lukasz. Effect of screw angulation on the bending performance of polyaxial locking interfaces: a micro-CT evaluation.. Scientific reports. 2023. DOI: 10.1038/s41598-023-48791-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.