Sternal closure with sandwiched three-piece bioresorbable mesh reduces postoperative hemorrhage: a retrospective study.

Yokoyama Yasutaka, Yamamoto Taira, Oyama Tetsuma, Lee Jiyoung, Machida Yoichiro, Endo Daisuke, Sato Yuichiro, Dohi Shizuyuki, Amano Atsushi, Tabata Minoru

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Median sternotomy is the most performed procedure in cardiac surgery; however, sternal displacement and bleeding remains a problem. This study aimed to investigate whether sternal reconstruction using a sandwiched three-piece bioresorbable mesh plate can prevent postoperative sternal displacement and bleeding more than a bioresorbable pin.

METHODS

Patients (n = 218) who underwent median sternotomy were classified according to whether a sandwiched three-piece bioresorbable mesh plate and wire cerclage (group M, n = 109) or a bioresorbable pin and wire cerclage (group P, n = 109) were used during sternal reconstruction. The causes of postoperative sternal displacement and bleeding with computed tomography data were analyzed and compared between the groups.

RESULTS

The preoperative patient characteristics did not significantly differ between the groups. However, the evaluation of sternal and substernal hematoma on postoperative day 5 using computed tomography showed sternal displacement in 4 (4%) and 22 (20%) patients, and substernal hematoma in 17 (16%) and 41 (38%) patients in groups M and P, respectively; this difference was significant. Furthermore, the amount of bleeding at 6 h postoperatively was lower in group M than in group P (235 ± 147 vs. 284 ± 175 mL, p = 0.0275). Chest reopening, intubation time, and length of intensive care unit and hospital stays did not differ between the groups. The evaluation of substernal hematoma based on computed tomography yielded a significantly lower for group M than for group P, revealing that the mesh plate was an independent predictor of substernal hematoma prevention.

CONCLUSION

Sternal fixation with a three-piece bioresorbable mesh plate could prevent postoperative sternal displacement, bleeding, and substernal hematoma more than sternal fixation with a pin.

Для цитирования: Yokoyama Yasutaka, Yamamoto Taira, Oyama Tetsuma, Lee Jiyoung, Machida Yoichiro, Endo Daisuke, Sato Yuichiro, Dohi Shizuyuki, Amano Atsushi, Tabata Minoru. Sternal closure with sandwiched three-piece bioresorbable mesh reduces postoperative hemorrhage: a retrospective study.. Journal of cardiothoracic surgery. 2023. DOI: 10.1186/s13019-023-02460-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.