MedElevator Войти в исследования
← Поиск публикаций

DOI 10.7507/1002-1892.202308005

Медицинская библиотека · Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2023

[Treatment of Ideberg type Ⅱ scapular glenoid fracture with compression screw combined with Buttress plate through direct axillary approach].

Zhang Jianping, Liu Hui, Xu Weizhen, Xiong Yuanfei, Zhang Jinhui, Wu Jin

Аннотация на английскомСтатьяПеревод в очереди

Аннотация

OBJECTIVE

To investigate the effectiveness of compression screw combined with Buttress plate through direct axillary approach for Ideberg typeⅡ scapular glenoid fractures.

METHODS

A retrospective analysis was conducted on 11 patients with Ideberg type Ⅱ scapular glenoid fractures treated with compression screws combined with Buttress plate fixation through the direct axillary approach between January 2014 and June 2022. There were 7 males and 4 females, aged from 34 to 75 years, with an average of 56.0 years. The causes of injury included 4 cases of falling from height injury, 4 cases of heavy object injury, and 3 cases of traffic accident injury. The time from injury to operation was 2-5 days, with an average of 3.8 days. The operation time, intraoperative blood loss, hospital stay, complications, and fracture healing time were recorded. The Constant-Murley score, American Society of Shoulder and Elbow Surgeons (ASES) score, and shoulder joint flexion, abduction, external rotation (neutral position), and internal rotation (neutral position) range of motion were used to evaluate shoulder joint pain and function.

RESULTS

The operation time was 45-105 minutes, with an average of 79.0 minutes; the intraoperative blood loss was 80-200 mL, with an average of 99.2 mL; the hospital stay was 3-8 days, with an average of 5.8 days. One patient had poor wound healing after operation, and the wound healed after strengthening dressing change; the rest wounds had primary healing, and no axillary nerve paralysis occurred. Except for 1 patient lost follow-up, the remaining 10 patients were followed up 10-54 months, with an average of 26.4 months. The postoperative X-ray film examination showed that the fractures healed well within 8-15 weeks, with an average of 11.0 weeks. There was no complication such as fracture displacement, internal fixator failure or fracture during follow-up. At last follow-up, the patient's shoulder joint flexion, abduction, external rotation (neutral position), and internal rotation (neutral position) range of motion, Constant-Murley score, and ASES score significantly improved when compared with those before operation ( P<0.05).

CONCLUSION

Compression screw combined with Buttress plate through direct axillary approach is an effective way to treat Ideberg typeⅡ scapular glenoid fracture, with advantages of small trauma, concealed incision, and good effectiveness.

Для цитирования: Zhang Jianping, Liu Hui, Xu Weizhen, Xiong Yuanfei, Zhang Jinhui, Wu Jin. [Treatment of Ideberg type Ⅱ scapular glenoid fracture with compression screw combined with Buttress plate through direct axillary approach].. Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery. 2023. DOI: 10.7507/1002-1892.202308005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.