DOI 10.1097/mnm.0000000000001390
99mTc-white blood cell SPECT/CT to assess diabetic foot osteomyelitis remission: contribution of semi-quantitative scoring system.
Аннотация
AIMS: We previously reported that 99mTc-White blood cell (WBC) single-photon emission computed tomography (SPECT/CT) could be a useful tool to assess diabetic foot osteomyelitis (DFO) remission and guide the duration of antibiotic treatment. The aim of the present study was to evaluate the performance and reproducibility of two analysis methods to diagnose DFO remission using 99mTc-WBC-SPECT/CT.
METHODS
99mTc-WBC-SPECT/CT performed for patients with DFO at the end of antibiotic treatment were retrospectively read by two nuclear physicians (one senior and one junior). Assessment by conventional visual analysis and by the use of a semi-quantitative scoring system, the composite score index (CSI), was performed. The performance and reproducibility of methods were compared between the two nuclear physicians. Successful treatment of DFO was defined by the absence of DFO relapse at the same site within 1 year.
RESULTS
A total of 68 patients with 74 DFO were included. Three were excluded from the analysis due to the low quality of SPECT/CT; among the 71 DFO analyzed, 11 (15.5%) had a relapse during follow-up. Performances of 99mTc-WBC-SPECT/CT to predict DFO remission with conventional visual assessment were significantly lower for junior than for senior nuclear physician with moderate inter-rater agreement (Kappa: 0.417). Performances with the use of CSI were similar between the two readers with good inter-rater agreement (Kappa: 0.756).
CONCLUSION
The study found that conventional visual assessment of 99mTc-WBC-SPECT/CT to assess DFO remission requires experience, and supported that CSI could be useful for junior nuclear physician to discriminate residual infections and inflammatory post-treatment uptake.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.