DOI 10.1177/230949900801600109
Dynamic hip screw and compression plate fixation of ipsilateral femoral neck and shaft fractures.
Аннотация
PURPOSE: To evaluate surgical outcomes of ipsilateral femoral neck and shaft fractures.
METHODS
Between April 1997 and September 2004, 29 men and 8 women (mean age, 37 years) underwent fixation of femoral neck and shaft fractures using a dynamic compression plate plus a dynamic hip screw or screws. There were 30 femoral neck and 7 pertrochanteric fractures. Functional results were assessed according to the Friedman and Wyman classification.
RESULTS
The mean follow-up period was 49 months. Of the femoral neck fractures, 34 united in a mean of 4 months; 33 of them healed anatomically and one with a 6-degree varus angulation. No osteonecrosis of the femoral head was noted. Of the femoral shaft fractures, 32 united in a mean of 6 months, 5 were non-unions (2 persisted even after revision surgery). Seven patients developed infections (5 superficial and 2 deep), which resolved with debridement and antibiotic treatment. Functional results were good in 29 patients, fair in 5, and poor in 3.
CONCLUSION
The use of dynamic hip screws and compression plates for ipsilateral femoral neck and shaft fractures is reliable in achieving bone union with few complications.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.