OBJECTIVES

Recent studies have shown that complement hyperactivation contributes to development of thrombotic microangiopathy. The evaluation of complement biomarkers is known to be influenced by inappropriate specimen handling. However, there has been no study fully addressing this topic.

METHODS

Blood from each donor was subjected to 62 different handling conditions prior to complement assays.

RESULTS

Complement biomarkers (C4d/C3a/factor Bb/C5a/C5b-9) are stable at room temperature (RT) for up to 4 hours in whole blood containing citrate or EDTA. However, under similar conditions, levels of C4d and C3a were significantly higher in serum than those in plasma. Thawing of the samples on ice or at RT had no significant effect on complement levels. In contrast, thawing at 37°C resulted in striking increases in levels of the complement system in serum and citrated plasma but not in EDTA plasma. Up to four freeze/thaw cycles on ice or RT did not substantially increase the levels of C3a, factor Bb, C5a, and C5b-9 but had a significant effect on C4d. Long-term storage of citrated plasma at -80°C for up to 6 years had no significant effect on levels of complement factors.

CONCLUSIONS

The results from this study thus provide crucial guidelines for future investigations using complement biomarkers to define the role of complement system in disease.

Для цитирования: Yang Shangbin, McGookey Michael, Wang Yi, Cataland Spero R, Wu Haifeng M. Effect of blood sampling, processing, and storage on the measurement of complement activation biomarkers.. American journal of clinical pathology. 2015. DOI: 10.1309/ajcpxpd7zqxntial.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.