Paquis P, Breuil V, Lonjon M, Euller-Ziegler L, Grellier P

Клинический случайКлиническое исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVES

Occipitocervical fixation is used for the treatment of nontraumatic upper cervical instabilities. To date, plates have been fixed with screws or wires. However, these devices are not indicated in the treatment of patients with severe osteoporosis or in instances of significant thinning of the occipital bone. We performed a clinical trial of a new type of fixation that uses cervical interlaminar hooks and occipital claws with hooks or with screws (CCD type; Sofamor-Danek, Roissy, France) for the treatment of nontraumatic upper cervical instabilities.

METHODS

Five women and one man ranging in age from 28 to 72 years (average age, 54 yr) were thus treated. The CCD type material had two rod plates and hooks allowing the proper placement of interlaminar and occipital claws. The occipital plate can also be directly screwed to the bone. Occipital hooks were used in four patients. The other two patients, who had occipitocervical congenital abnormalities that required an occipitocervical opening and an additional dural enlargement, underwent occipital screw fixation because of the previous opening of the foramen magnum. A cancellous iliac autograft allowed the usual fusion.

RESULTS

No postoperative complications were observed, and all patients experienced significant improvement of their neck pain. Four patients had neurological symptoms. The condition of two patients improved, and the condition of the other two stabilized.

CONCLUSION

This report confirms the interest of the CCD method to correct all types of upper cervical instabilities, even in cases of unusual thinning of the occipital bone or in osteoporotic states.

Для цитирования: Paquis P, Breuil V, Lonjon M, Euller-Ziegler L, Grellier P. Occipitocervical fixation using hooks and screws for upper cervical instability.. Neurosurgery. 1999. DOI: 10.1097/00006123-199902000-00042.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.