Validity of a wrist-worn consumer-grade wearable for estimating energy expenditure, sedentary behaviour, and physical activity in manual wheelchair users with spinal cord injury.

Bailey Daniel P, Ahmed Imran, Cooper Daniel L, Finlay Katherine A, Froome Hannah M, Nightingale Tom E, Romer Lee M, Goosey-Tolfrey Vicky L, Ferrandino Louise

СтатьяВалидационное исследованиеПеревод в очереди

Аннотация

PURPOSE: To evaluate the validity of a consumer-grade wearable for estimating energy expenditure, sedentary behaviour, and physical activity in manual wheelchair users with spinal cord injury (SCI).

MATERIALS AND

METHODS

Fifteen manual wheelchair users with SCI (C5-L1, four female) completed activities of daily living and wheelchair propulsion (2-8 km·h-1). Wrist-worn accelerometry data were collected using consumer-grade (z-Track) and research-grade (ActiGraph GT9X) devices. Energy expenditure was measured via indirect calorimetry. Linear regression was used to evaluate the prediction of criterion metabolic equivalent of task (MET) by each accelerometer's vector magnitude (VM). Area under the receiver operating characteristic curve (ROC-AUC) evaluated the accuracy of VM for discriminating between physical activity intensities and for identifying accelerometer cut-points.

RESULTS

Standardised β-coefficients for the association between z-Track and ActiGraph VM for criterion MET were 0.791 (p < 0.001) and 0.774 (p < 0.001), respectively. The z-Track had excellent accuracy for classifying time in sedentary behaviour (ROC-AUC = 0.95) and moderate-to-vigorous physical activity (ROC-AUC = 0.93); similar values to the ActiGraph (ROC-AUC = 0.96 and 0.88, respectively). Cut-points for the z-Track were ≤37 g·min-1 for sedentary behaviour and ≥222 g·min-1 for moderate-to-vigorous physical activity.

CONCLUSIONS

This study supports the validity of a consumer-grade wearable to measure sedentary time and physical activity in manual wheelchair users with SCI.

Для цитирования: Bailey Daniel P, Ahmed Imran, Cooper Daniel L, Finlay Katherine A, Froome Hannah M, Nightingale Tom E, Romer Lee M, Goosey-Tolfrey Vicky L, Ferrandino Louise. Validity of a wrist-worn consumer-grade wearable for estimating energy expenditure, sedentary behaviour, and physical activity in manual wheelchair users with spinal cord injury.. Disability and rehabilitation. Assistive technology. 2024. DOI: 10.1080/17483107.2024.2405895.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.