MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/03635465211015192

Медицинская библиотека · The American journal of sports medicine · 2021

Stacked Biocomposite Screws in a Single-Stage Revision Anterior Cruciate Ligament Reconstruction Has Acceptable Fixation Strength in a Porcine Cadaveric Model.

Baydoun Hasan, Engler Ian D, Hosseini Ali, LeClere Lance, Zoon Joeri, Zoon Luciano, Li Guoan, Salzler Matthew J, Gill Thomas J

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Stacked screws is a commonly used technique in single-stage revision anterior cruciate ligament (ACL) reconstruction in the setting of bone loss, but there are limited data to support its use.

HYPOTHESIS: Two configurations of a biocomposite stacked screws construct have similar fixation strength and linear stiffness as a primary ACL reconstruction construct in a biomechanical model.

STUDY

DESIGN

Controlled laboratory study.

METHODS

A total of 30 porcine legs were divided into 3 groups. Group 1 underwent primary ACL reconstruction with a patellar tendon graft fixed into the femur, with an 8-mm biocomposite interference screw of beta-tricalcium phosphate and poly lactide-co-glycolide. For a revision ACL reconstruction model, groups 2 and 3 had bone tunnels created and subsequently filled with 12-mm biocomposite screws. New bone tunnels were drilled through the filler screw and the surrounding bone, and the patellar bone plug was inserted. Group 2 was fixed with 8-mm biocomposite screws on the side of the graft opposite the filler screw, while group 3 had the interference screw interposed between the graft and the filler screw. The construct was loaded at 1.5 mm/s in line with the tunnel until failure. Load to failure, linear stiffness, and mode of failure were recorded.

RESULTS

The mean pullout strength for groups 1, 2, and 3 was 626 ± 145 N, 653 ± 152 N, and 720 ± 125 N, respectively (P = .328). The mean linear stiffness of the construct in groups 1, 2, and 3 was 71.4 ± 9.9 N/mm, 84.1 ± 11.1 N/mm, and 82.0 ± 10.8 N/mm, respectively. Group 2 was significantly stiffer than group 1 (P = .037).

CONCLUSION

Two configurations of a biocomposite stacked screws construct for a single-stage revision ACL reconstruction in the setting of bone loss show a similar fixation strength and linear stiffness to a primary ACL reconstruction at time zero in a porcine model.

CLINICAL RELEVANCE: In the setting of bone loss from tunnel malpositioning, a single-stage revision ACL reconstruction using a stacked screws construct may provide adequate fixation strength and linear stiffness.

Для цитирования: Baydoun Hasan, Engler Ian D, Hosseini Ali, LeClere Lance, Zoon Joeri, Zoon Luciano, Li Guoan, Salzler Matthew J, Gill Thomas J. Stacked Biocomposite Screws in a Single-Stage Revision Anterior Cruciate Ligament Reconstruction Has Acceptable Fixation Strength in a Porcine Cadaveric Model.. The American journal of sports medicine. 2021. DOI: 10.1177/03635465211015192.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.