Medium-term results of ceramic-on-polyethylene Zweymüller-Plus total hip arthroplasty.
Аннотация
INTRODUCTION
The need for better durability and longevity in total hip arthroplasty for patients with various hip joint diseases remains a challenge. This study aimed to obtain medium-term results at a follow-up of >10 years for Zweymüller-Plus total hip arthroplasty with ceramic-on-polyethylene bearing.
METHODS
A retrospective study was conducted to review the results after a minimum of 12.4 years of 207 consecutive total hip arthroplasties in 185 patients in Peking University People's Hospital in China using the Zweymüller SL-Plus stem in combination with the Bicon-Plus threaded cup and ceramic-on-polyethylene bearing between October 1994 and April 2000.
RESULTS
During the study period, two patients (2 hips) died and 25 patients (28 hips) were lost to follow-up. Two hips were revised for aseptic loosening of the Bicon-Plus cup. The mean clinical and radiological follow-up was 14.1 years (range, 12.4-16.5 years) for the remaining 156 patients (175 hips). The mean (standard deviation) Harris Hip score for the 175 hips increased significantly from 39.3 (3.8) preoperatively to 94.1 (2.5) postoperatively at a mean follow-up of 14.1 years (P<0.05). Focal osteolysis was observed in seven (4.0%) of 175 stems and three (1.7%) of 175 cups. The Kaplan-Meier survival with revision for any reason as the end-point was 99.03% (95% confidence interval, 95%-100%).
CONCLUSIONS
The high survival rate of the cementless Zweymüller-Plus system with ceramic-on-polyethylene bearing at mid-term follow-up makes this total hip arthroplasty system reliable for patients with various hip joint diseases.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.