MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/0284185117731448

Медицинская библиотека · Acta radiologica (Stockholm, Sweden : 1987) · 2017

Apparent diffusion coefficient (ADC) does not correlate with different serological parameters in myositis and myopathy.

Meyer Hans-Jonas, Ziemann Oliver, Kornhuber Malte, Emmer Alexander, Quäschling Ulf, Schob Stefan, Surov Alexey

СтатьяПеревод в очереди

Аннотация

Background Magnetic resonance imaging (MRI) is widely used in several muscle disorders. Diffusion-weighted imaging (DWI) is an imaging modality, which can reflect microstructural tissue composition. The apparent diffusion coefficient (ADC) is used to quantify the random motion of water molecules in tissue. Purpose To investigate ADC values in patients with myositis and non-inflammatory myopathy and to analyze possible associations between ADC and laboratory parameters in these patients. Material and Methods Overall, 17 patients with several myositis entities, eight patients with non-inflammatory myopathies, and nine patients without muscle disorder as a control group were included in the study (mean age = 55.3 ± 14.3 years). The diagnosis was confirmed by histopathology in every case. DWI was obtained in a 1.5-T scanner using two b-values: 0 and 1000 s/mm2. In all patients, the blood sample was acquired within three days to the MRI. The following serological parameters were estimated: C-reactive protein, lactate dehydrogenase, alanine aminotransferase, aspartate aminotransferase, creatine kinase, and myoglobine. Results The estimated mean ADC value for the myositis group was 1.89 ± 0.37 × 10-3 mm2/s and for the non-inflammatory myopathy group was 1.79 ± 0.33 × 10-3 mm2/s, respectively. The mean ADC values (1.15 ± 0.37 × 10-3 mm2/s) were significantly higher to unaffected muscles (vs. myositis P = 0.0002 and vs. myopathy P = 0.0021). There were no significant correlations between serological parameters and ADC values. Conclusion Affected muscles showed statistically significantly higher ADC values than normal muscles. No linear correlations between ADC and serological parameters were identified.

Для цитирования: Meyer Hans-Jonas, Ziemann Oliver, Kornhuber Malte, Emmer Alexander, Quäschling Ulf, Schob Stefan, Surov Alexey. Apparent diffusion coefficient (ADC) does not correlate with different serological parameters in myositis and myopathy.. Acta radiologica (Stockholm, Sweden : 1987). 2017. DOI: 10.1177/0284185117731448.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.