MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5301/hipint.5000435

Медицинская библиотека · Hip international : the journal of clinical and experimental research on hip pathology and therapy · 2017

Survival of hydroxyapatite-coated cups: acetabular screws involve a lower rate of revision surgery due to aseptic loosening.

Natera Luis, Valera Marius, Gómez Esther Moya, Ibañez Natalia, Crusi Xavier, Sancho Rogelio

Сравнительное исследованиеСтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

BACKGROUND

It is believed that the path of acetabular screws may represent a shuttle between hydroxyapatite (HA) particles and the liner. The aim was to assess the relationship between acetabular screws and revision surgery for aseptic loosening in total hip arthroplasties (THAs).

MATERIAL AND

METHODS

A retrospective multicentric study was performed. Patients older than 18 years and patients who underwent THA with both the stem and cup HA-coated were included. The rate of revision-surgery considering only aseptic loosening was calculated. The proportion of cases in which acetabular screws were used was registered, as well as the proportion of cups that showed osteolysis. The statistical relationship between acetabular screws and osteolysis, as well as acetabular screws and revision-surgery for aseptic loosening were assessed.

RESULTS

There were 749 cases. Mean age 62.1 (45-84) years. Mean follow-up 14.19 (8.9-16.7) years. Revision surgery was performed in 12.8% (96/749) of the cups. 73.95% (71/96) of the revised cups showed aseptic loosening. The overall 15-year survival of the cups considering only aseptic loosening was 84.4%. Acetabular screws were used in 47.5% (356/749) of the cups. Acetabular screws were used in 40.44% (55/136) of the cups that showed osteolysis. The use of acetabular screws was associated with less osteolysis (p = 0.006). Acetabular screws were used in 35.21% (25/71) of the cups that were revised for aseptic loosening. The use of acetabular screws was associated with a lower rate of revision surgery (p = 0.020).

CONCLUSIONS

In THA with the stem and cup HA-coated, the use of acetabular screws is associated with a lower rate of revision surgery.

Для цитирования: Natera Luis, Valera Marius, Gómez Esther Moya, Ibañez Natalia, Crusi Xavier, Sancho Rogelio. Survival of hydroxyapatite-coated cups: acetabular screws involve a lower rate of revision surgery due to aseptic loosening.. Hip international : the journal of clinical and experimental research on hip pathology and therapy. 2017. DOI: 10.5301/hipint.5000435.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.