DOI 10.1007/s00276-021-02749-y
Measuring stiffness of normal medial collateral ligament in healthy volunteers via shear wave elastography.
Аннотация
PURPOSE: We aim to determine a reference data set for normal medial collateral ligament (MCL) stiffness values using shear wave elastography (SWE).
METHODS
Quantitative stiffness of the MCL was measured at three levels: the proximal (MCL area from the level of the medial meniscus to the level of the femoral attachment), the middle (MCL area at the level of the medial meniscus), and the distal (MCL area from the level of the medial meniscus to the level of the tibial attachment) segments of the MCL at a knee position of 0°.
RESULTS
A total of 60 MCL of 30 healthy volunteers (15 female, 15 male) were examined. The mean stiffness values of the proximal, middle, and distal MCL for observer 1 were 32.25 ± 6.44, 34.25 ± 6.84, and 35.47 ± 6.98, respectively. The mean stiffness values of the proximal, middle, and distal MCL for observer 2 were 33.56 ± 6.76, 35.44 ± 6.91, and 36.32 ± 7.04, respectively.
CONCLUSION
SWE has a strong potential to be a method of choice for evaluating MCL stiffness. Our study participants were healthy volunteers and the data can be used as reference data for future studies.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.