m+Medelevator.RU
← Поиск публикаций
Journal of shoulder and elbow surgery · 2017

Clinical and radiographic outcome of revision surgery of total elbow prosthesis: midterm results in 19 cases.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Viveen Jetske, Prkic Ante, Koenraadt Koen L M, Kodde Izaäk F, The Bertram, Eygendaal Denise

Аннотация

BACKGROUND: The aim of this study is to report on the midterm outcomes and complications of revision surgery of total elbow arthroplasty.

METHODS: All patients who had undergone total elbow arthroplasty revision surgery between 2009 and 2014 with semiconstrained total elbow prostheses were prospectively enrolled in the study. Records were reviewed for demographic data; baseline measurements; and several follow-up assessments including the Mayo Elbow Performance Score (MEPS), visual analog scale (VAS) score for pain, Oxford Elbow Score, range of motion, satisfaction, and radiographs.

RESULTS: A total of 19 revision arthroplasties were included. At a mean follow-up of 57 months, there had been 1 rerevision and 2 removals. One patient was excluded from follow-up because of confounding comorbidity. At last follow-up, MEPS values and VAS pain scores both improved (P < .01). The rate of combined good and excellent results on the MEPS was 53%. The mean VAS scores for pain at rest and with activity were 2 and 4, respectively. Fair results for the Oxford Elbow Score were reported, with a mean score of 28 points. Range of motion improved to an average flexion-extension arc of 108° (P < .01), and the pronation-supination arc improved to an average of 123° (P < .01). All elbows were stable at last follow-up (P < .01). Radiographs showed nonprogressive osteolysis around the prosthesis in 3 cases (19%) and suspicion of loosening in 1 (6%). In 11 patients postoperative complications occurred. Of 15 patients, 13 (87%) were satisfied with the result of the revision procedure.

CONCLUSION: Revision of total elbow prostheses leads to satisfactory results, less pain, and better elbow function. This procedure is related to a relatively high complication rate.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты