MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jtos.2021.06.005

Медицинская библиотека · The ocular surface · 2021

Long-term outcomes of the MICOF keratoprosthesis surgery.

Wang Liqiang, He Xiezhou, Wang Qun, Wu Tengyun, Liu Anqi, Huang Yifei

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To evaluate long-term anatomical and functional outcomes of the MICOF keratoprosthesis to treat end-stage corneal blindness.

DESIGN

Retrospective review of consecutive clinical case series.

PARTICIPANTS

Between October 2000 and October 2015, at the Department of Ophthalmology of Chinese PLA General Hospital (PLAGH), a total of 132 eyes of 131 patients had undergone a MICOF keratoprosthesis implantation. Of those, 91 eyes of 90 patients were included in this study.

METHODS

Preoperative information, surgical procedures, and postoperative data were collected for each included eye.

MAIN OUTCOME MEASURES: Best-corrected visual acuity (BCVA), keratoprosthesis retention, and significant postoperative complications were reported.

RESULTS

The most common indications for surgery were chemical or thermal burns (68.1%, 62 of 91 eyes) and explosive injury (12.1%, 11 of 91 eyes), followed by Stevens-Johnson Syndrome (10.0%, 9 of 91 eyes), Sjögren's syndrome (4.4%, 4 of 91 eyes), mucous membrane pemphigoid (3.3%, 3 of 91 eyes) and multi-penetrating keratoplasty failure (2.2%, 2 of 91 eyes). The mean follow-up duration was 8.38 ± 3.22 years (range: 5-17.25 years, median: 7.67 years). All patbients had a preoperative visual acuity of hand motions or worse. A MICOF keratoprosthesis significantly improved patients' visual function with bilateral end-stage corneal blindness. Postoperative visual acuity improved to 20/200 or better in 41 eyes (45.1%, of 91 eyes) and to 20/100 or better in 32 eyes (35.2% of 91 eyes) at the last follow-up visit. Preexisting glaucoma was present in 17 (18.7% of 91 eyes). The most common postoperative complications were overgrowth of the surface mucosa (31.9%, 29 of 91 eyes), glaucoma (25.3%, 23 of 91 eyes), retro-prosthetic membrane (15.4%, 14 of 91 eyes), keratoprosthesis device extrusion (15.4%, 14 of 91 eyes), superficial tissue thinning (14.3%, 13 of 91 eyes), endophthalmitis (13.2%, 12 of 91 eyes), titanium frame exposure (13.2%, 12 of 91 eyes), optical cylinder ante-displacement (13.2%, 12 of 91 eyes), cornea melting (7.7%, 7 of 91 eyes), retinal detachment (6.6%, 6 of 91 eyes) and aqueous humour leakage (2.2%, 2 of 91 eyes). 84.6% (77 of 91 eyes) of the eyes retained their initial keratoprosthesis at the latest follow-up.

CONCLUSIONS

A MICOF keratoprosthesis is a reliable approach to rescue vision in end-stage corneal blinded patients and has better retention than a Boston Kpro TypeⅡ.

Для цитирования: Wang Liqiang, He Xiezhou, Wang Qun, Wu Tengyun, Liu Anqi, Huang Yifei. Long-term outcomes of the MICOF keratoprosthesis surgery.. The ocular surface. 2021. DOI: 10.1016/j.jtos.2021.06.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.