MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s13018-023-04256-9

Медицинская библиотека · Journal of orthopaedic surgery and research · 2023

What is the stable internal fixation for the unstable and osteoporotic supracondylar femoral fractures: a finite element analysis.

Rao Jianwei, Zhang Junchao, Ye Zhou, Zhang Liguang, Xu Jiangbao

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Osteoporotic supracondylar femoral fractures (OSFF) have historically been managed by the lateral anatomical locking plate with reasonable success. However, for some kinds of unstable and osteoporotic supracondylar femoral fractures (UOSFF), especially with bone defects, unilateral locking plate (ULLP) fixation failed or resulted in implant breakage. This paper is going to explore what is the stable internal fixation for UOSFF by adding the bilateral locking plate (BLLP) fixation.

METHODS

OSFF models were divided into two groups according to the fracture line type, which would be further subdivided according to their angle of fracture line, presence of bone defect, location, and degree of bone defect. Thereafter, kinds of locking plate fixation were constructed. A 2010-N load was applied to the femoral head, and a 1086-N load was applied to the greater trochanter. In this condition, the maximum von Mises stress distribution of models were investigated.

RESULTS

Firstly, it was obviously found that the stress concentration in the BLLP group was more dispersed than that in the ULLP group. Secondly, according to the fracture line analysis, the stress value of fracture line type in "\" model group was higher than that of "/" model group. Moreover, with the increase in fracture line angle, the stress value of the model increased. Thirdly, from the bone defect analysis, the stress value of the medial bone defect (MBD) model group was higher than that of the lateral bone defect (LBD) model group. And as the degree of bone defect increased, the stress value increased gradually in the model group.

CONCLUSION

In the following four cases, lateral unilateral locking plate fixation cannot effectively stabilize the fracture end, and double locking plate internal fixation is a necessary choice. First, when the angle of the fracture line is large (30, 45). Second, when the fracture line type is "/." Third, when the bone defect is large. Fourth, when the bone defect is medial.

Для цитирования: Rao Jianwei, Zhang Junchao, Ye Zhou, Zhang Liguang, Xu Jiangbao. What is the stable internal fixation for the unstable and osteoporotic supracondylar femoral fractures: a finite element analysis.. Journal of orthopaedic surgery and research. 2023. DOI: 10.1186/s13018-023-04256-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.