MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3899/jrheum.171490

Медицинская библиотека · The Journal of rheumatology · 2018

Ultrasound of Subtalar Joint Synovitis in Patients with Rheumatoid Arthritis: Results of an OMERACT Reliability Exercise Using Consensual Definitions.

Bruyn George A W, Siddle Heidi J, Hanova Petra, Costantino Félicie, Iagnocco Annamaria, Delle Sedie Andrea, Gutierrez Marwin, Hammer Hilde B, Jernberg Elizabeth, Loeille Damien, Micu Mihaela C, Moller Ingrid, Pineda Carlos, Richards Bethan, Stoenoiu Maria S, Suzuki Takeshi, Terslev Lene, Vlad Violeta, Wonink Robert, d'Agostino Maria-Antonietta, Wakefield Richard J

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАСистематический обзорПеревод в очереди

Аннотация

OBJECTIVE

To evaluate the intraobserver and interobserver reliability of the ultrasonographic (US) assessment of subtalar joint (STJ) synovitis in patients with rheumatoid arthritis (RA).

METHODS

Following a Delphi process, 12 sonographers conducted an US reliability exercise on 10 RA patients with hindfoot pain. The anteromedial, posteromedial, and posterolateral STJ was assessed using B-mode and power Doppler (PD) techniques according to an agreed US protocol and using a 4-grade semiquantitative grading score for synovitis [synovial hypertrophy (SH) and signal] and a dichotomous score for the presence of joint effusion (JE). Intraobserver and interobserver reliability were computed by Cohen's and Light's κ. Weighted κ coefficients with absolute weighting were computed for B-mode and PD signal.

RESULTS

Mean weighted Cohen's κ for SH, PD, and JE were 0.80 (95% CI 0.62-0.98), 0.61 (95% CI 0.48-0.73), and 0.52 (95% CI 0.36-0.67), respectively. Weighted Cohen's κ for SH, PD, and JE in the anteromedial, posteromedial, and posterolateral STJ were -0.04 to 0.79, 0.42-0.95, and 0.28-0.77; 0.31-1, -0.05 to 0.65, and -0.2 to 0.69; 0.66-1, 0.52-1, and 0.42-0.88, respectively. Weighted Light's κ for SH was 0.67 (95% CI 0.58-0.74), 0.46 (95% CI 0.35-0.59) for PD, and 0.16 (95% CI 0.08-0.27) for JE. Weighted Light's κ for SH, PD, and JE were 0.63 (95% CI 0.45-0.82), 0.33 (95% CI 0.19-0.42), and 0.09 (95% CI -0.01 to 0.19), for the anteromedial; 0.49 (95% CI 0.27-0.64), 0.35 (95% CI 0.27-0.4), and 0.04 (95% CI -0.06 to 0.1) for posteromedial; and 0.82 (95% CI 0.75-0.89), 0.66 (95% CI 0.56-0.8), and 0.18 (95% CI 0.04-0.34) for posterolateral STJ, respectively.

CONCLUSION

Using a multisite assessment, US appears to be a reliable tool for assessing synovitis of STJ in RA.

Для цитирования: Bruyn George A W, Siddle Heidi J, Hanova Petra, Costantino Félicie, Iagnocco Annamaria, Delle Sedie Andrea, Gutierrez Marwin, Hammer Hilde B, Jernberg Elizabeth, Loeille Damien, Micu Mihaela C, Moller Ingrid, Pineda Carlos, Richards Bethan, Stoenoiu Maria S, Suzuki Takeshi, Terslev Lene, Vlad Violeta, Wonink Robert, d'Agostino Maria-Antonietta, Wakefield Richard J. Ultrasound of Subtalar Joint Synovitis in Patients with Rheumatoid Arthritis: Results of an OMERACT Reliability Exercise Using Consensual Definitions.. The Journal of rheumatology. 2018. DOI: 10.3899/jrheum.171490.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.