DOI 10.2106/jbjs.15.01248

Медицинская библиотека · The Journal of bone and joint surgery. American volume · 2016

The Wear Rate of Highly Cross-Linked Polyethylene in Total Hip Replacement Is Not Increased by Large Articulations: A Randomized Controlled Trial.

Howie Donald W, Holubowycz Oksana T, Callary Stuart A

СтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Larger articulations reduce the risk of dislocation following primary total hip arthroplasty, leading to increased use of these articulations. The wear rate of highly cross-linked polyethylene (XLPE) is low in standard-diameter articulations but remains unclear in larger articulations. The aim of this randomized controlled trial was to compare the mean wear rates of 36-mm and 28-mm metal-on-XLPE articulations between 1 and 3 years postoperatively.

METHODS

Fifty-six elderly patients undergoing primary total hip arthroplasty were randomized intraoperatively to receive either a 36-mm or 28-mm metal-on-XLPE articulation. Factors that may affect wear were controlled by study design. Wear was measured using radiostereometric analysis.

RESULTS

Mean annual proximal wear rates between 1 and 3 years were 0.00 and 0.01 mm/yr for the 36 and 28-mm articulation cohorts, respectively. No patient had a proximal wear rate of >0.1 mm/yr. Mean wear was very low in all directions, and the wear rate of 36-mm articulations was not significantly greater than that of 28-mm articulations on the basis of proximal, medial 2-dimensional, and 3-dimensional wear.

CONCLUSIONS

The wear rate of a larger 36-mm metal-on-XLPE articulation between 1 and 3 years following primary total hip arthroplasty was low and no greater than that of a 28-mm articulation. However, before a 36-mm metal-on-XLPE articulation is widely recommended, particularly in young active patients, long-term wear rates and association between wear and periprosthetic osteolysis should be determined.

LEVEL OF EVIDENCE: Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence.

Для цитирования: Howie Donald W, Holubowycz Oksana T, Callary Stuart A. The Wear Rate of Highly Cross-Linked Polyethylene in Total Hip Replacement Is Not Increased by Large Articulations: A Randomized Controlled Trial.. The Journal of bone and joint surgery. American volume. 2016. DOI: 10.2106/jbjs.15.01248.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.