MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jos.2025.08.005

Медицинская библиотека · Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association · 2025

Validation of Hounsfield units for preoperative bone mineral density assessment in intertrochanteric femoral fractures.

Eto Shuichi, Imanishi Shunji, Komuta Wataru, Oba Yosuke, Hidaka Nobumichi

СтатьяВалидационное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Hounsfield units (HU) on computed tomography (CT) are strongly correlated with bone mineral density (BMD) and may aid in osteoporosis screening. However, there is no standardized method for assessing bone density in displaced femoral head fractures. This study aimed to measure HU values in the femoral head using preoperative post-fracture CT images of patients with intertrochanteric femoral fractures and investigate whether it correlated with BMD measured by dual-energy X-ray absorptiometry (DXA).

MATERIALS AND

METHODS

We retrospectively analyzed post-fracture CT images of intertrochanteric fractures (n = 52). Hounsfield units were measured in the axial, coronal, and sagittal planes using the femoral neck axis as a reference. Severe osteoporosis was defined as <60 % of the young adult mean (YAM) (T-score <-3.3). We evaluated the correlations between HU and DXA-derived BMD, along with reliability (intraclass correlation coefficient [ICC]), measurement bias (Bland-Altman analysis), and diagnostic performance (receiver operating characteristic [ROC]).

RESULTS

HU values demonstrated strong associations with BMD across all planes, with the highest correlations observed in the axial and coronal planes. ICC values exceeded 0.9, indicating excellent reliability. Bland-Altman analysis revealed no proportional bias but a fixed bias in the sagittal plane, whereas the narrowest limits of agreement were observed in the axial plane. Based on the ROC analysis, an axial HU cutoff of 151.5 identified severe osteoporosis (sensitivity, 0.756; specificity, 0.783).

CONCLUSIONS

Axial HU measurements were most reliable for assessing the bone quality. This cutoff value may help identify severe osteoporosis and determine eligibility for cement augmentation. However, further validation is needed.

Для цитирования: Eto Shuichi, Imanishi Shunji, Komuta Wataru, Oba Yosuke, Hidaka Nobumichi. Validation of Hounsfield units for preoperative bone mineral density assessment in intertrochanteric femoral fractures.. Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association. 2025. DOI: 10.1016/j.jos.2025.08.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.