Fluoroscopically guided interlaminar needle for lumbar disc herniation: a series of 43 patients.

Ahmed Adel, Kang Ahn, Hyung-Joon Jhun

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Lumbar disc herniation (LDH) is the most common cause of back and leg pain. We developed a specially designed needle and a minimally invasive interventional procedure to treat LDH.

OBJECTIVES

Assess outcomes of procedure and describe our methodology and clinical application.

DESIGN

Case series.

SETTING

A chronic pain management center.

PATIENTS AND

METHODS

Patients with LDH underwent fluoroscopically guided interventional interlaminar needling using a specially designed curved round needle. The outcome measures were evaluated three times: before the intervention and at 6 and 12 months after the intervention.

MAIN OUTCOME MEASURES: Visual analog scale (VAS) pain score, Oswestry Disability Index (ODI).

SAMPLE SIZE: 43 patients.

RESULTS

Six months after the intervention, the VAS pain score decreased by 5.1 (2.2) points and the ODI decreased by 30.7% (16.6%) compared to baseline. Twelve months after the intervention, the VAS pain score decreased by 6.2 (1.7) points and the ODI decreased by 36.9% (15.2%) compared to baseline.

CONCLUSIONS

This study suggests that fluoroscopically guided interventional interlaminar needling has clinical significance in managing pain resulting from LDH.

LIMITATIONS: This was an exploratory case series study. Additional studies and randomized clinical trials are needed to evaluate the efficacy of the technique compared to other treatments.

CONFLICT OF INTEREST: None.

Для цитирования: Ahmed Adel, Kang Ahn, Hyung-Joon Jhun. Fluoroscopically guided interlaminar needle for lumbar disc herniation: a series of 43 patients.. Annals of Saudi medicine. 2019. DOI: 10.5144/0256-4947.2019.417.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.