Influence of Cementation Mode and Ferrule Design on the Fatigue Resistance of Monolithic Zirconia Endocrowns.
Аннотация
Background
Classic endocrowns made of dental ceramics are considered a promising alternative to traditional post-endodontic restorations. The use of circular ferrules in endocrowns is a topic of controversial discussion. Therefore, the present study aims to evaluate the effect of ferrule design and cementation mode on the fatigue resistance of zirconia endocrowns.
Methods
Eighty human molars were divided into four groups (n = 20): NFC (no-ferrule, conventional cementation), NFA (no-ferrule, adhesive luting), FC (ferrule, conventional cementation) and FA (ferrule, adhesive luting). Both the classic and the modified endocrown preparation with a two-millimeter ferrule design were carried out. Endocrowns were fabricated from zirconia using the CEREC system. After thermocycling, specimens were loaded according to the step-stress test up to 1500 N.
Results
Failure rate was low; 88.8% of total specimens passed the step-stress test. Fractures were distributed between all groups; no significant differences in fatigue resistance were detected for preparation design and cementation mode.
Conclusions
Endocrowns appear to be a promising concept for endodontically treated molars. Ferrule and also cementation mode have only a minor influence on fatigue resistance of zirconia endocrowns. However, at very high forces, the marginal area of the ferrule represents a weak point.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.