MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/a-0612-7852

Медицинская библиотека · Ultrasound international open · 2018

The Value of an Automated Ultrasound System in the Detection of Synovitis.

Mueller Ruediger, Grunke Mathias, Wendler Jörg, Schuch Florian, Hofmann-Preiss Karina, Boettger Ina, Jakobs Rüdiger, Schulze-Koops Hendrik, von Kempis Johannes

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The detection of joint swelling caused by synovitis is important for the diagnosis of inflammatory arthritis. Ultrasound (US) and MRI have proven to be more sensitive and reliable than physical examination, but they are time-consuming and expensive. The automated breast volume scanner was developed to acquire serial B-mode pictures of the female breast and these can be analyzed in all three dimensions.

OBJECTIVES

To analyze the value of automated B-mode ultrasound employing the ABVS system in detecting synovitis of the finger joints compared to manual ultrasound (mUS) and physical examination, using MRI as the gold standard.

METHODS

19 consecutive patients suffering from active rheumatoid (n=15) or psoriatic (n=4) arthritis were included. Automated and mUS were conducted with a linear array (ACUSON S2000™, 11 MHz). Multiplanar reconstruction enabled examination of the images for the presence of synovitis.

RESULTS

90% of the hand joints were assessable by automated ultrasound. Automated US detected 12.0, mUS 14.2, MRI 13.4, and clinical examination 4.1 positive joints - i. e. joints with synovitis - on average per patient. The inter-observer reliability of both assessors for automated and mUS, MRI, and physical examination, was 66.9%, 72.7%, 95.1%, and 88.9%, respectively. 84.3% of the joints classified as positive on MRI were confirmed by automated ultrasound, 85.5% on mUS, and 36.0 on physical examination. This translated into a sensitivity of 83.5%, 85.5%, and 36.0% for the three methods, respectively.

Conclusion

Automated ultrasound is a promising ultrasound method for assessing small joints in patients with inflammatory arthritis.

Для цитирования: Mueller Ruediger, Grunke Mathias, Wendler Jörg, Schuch Florian, Hofmann-Preiss Karina, Boettger Ina, Jakobs Rüdiger, Schulze-Koops Hendrik, von Kempis Johannes. The Value of an Automated Ultrasound System in the Detection of Synovitis.. Ultrasound international open. 2018. DOI: 10.1055/a-0612-7852.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.