MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jacc.2009.05.075

Медицинская библиотека · Journal of the American College of Cardiology · 2009

Incidence and predictors of drug-eluting stent fracture in human coronary artery a pathologic analysis.

Nakazawa Gaku, Finn Aloke V, Vorpahl Marc, Ladich Elena, Kutys Robert, Balazs Isidora, Kolodgie Frank D, Virmani Renu

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

The aim of this study was to perform pathologic assessment on stent fracture.

BACKGROUND

Clinically, stent fracture has been reported in 1% to 2% of patients after drug-eluting stent (DES) implantation.

METHODS

High-contrast film-based radiographs of 177 consecutive lesions from the CVPath DES autopsy registry were reviewed. Stent fracture was graded as I (single-strut fracture), II (> or =2 struts), III (> or =2 struts with deformation), IV (with transection without gap), and V (with transection causing gap in stent segment). The incidence of adverse pathologic findings (thrombosis and restenosis) was assessed histologically.

RESULTS

Stent fracture was documented in 51 lesions (29%; grade I = 10, II = 14, III = 12, IV = 6, and V = 9). Lesions with stent fracture had longer duration after implantation (172 days [interquartile range (IQR) 31 to 630 days] vs. 44 days [IQR 7 to 270 days], p = 0.004), a higher rate of Cypher (Cordis Corp., Miami Lakes, Florida) stent usage (63% vs. 36%, p = 0.001), longer stent length (30.0 mm [IQR 22.0 to 40.0 mm] vs. 20.0 mm [IQR 14.0 to 27.3 mm], p < 0.0001), and a higher rate of overlapping stents (45% vs. 22%, p = 0.003). Although fracture with grade I to IV did not have significant impact on the occurrence of adverse pathologic findings such as thrombosis and restenosis, 67% of the grade V fracture lesions were associated with adverse pathologic findings at fracture sites. Longer stent length, use of Cypher, and longer duration of implant were identified as independent risk factors of stent fracture by logistic regression analysis.

CONCLUSIONS

The incidence of stent fracture was 29% lesions at autopsy, which is much higher than clinically reported. A high rate of adverse pathologic findings was observed in lesions with grade V stent fracture, whereas fracture with grade I to IV did not have a significant impact on the pathological outcome.

Для цитирования: Nakazawa Gaku, Finn Aloke V, Vorpahl Marc, Ladich Elena, Kutys Robert, Balazs Isidora, Kolodgie Frank D, Virmani Renu. Incidence and predictors of drug-eluting stent fracture in human coronary artery a pathologic analysis.. Journal of the American College of Cardiology. 2009. DOI: 10.1016/j.jacc.2009.05.075.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.