MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jhsa.2023.07.013

Медицинская библиотека · The Journal of hand surgery · 2023

The Effect of an Intraoperative Real-Time Counter on Radiation Exposure Events During Operative Treatment of Distal Radius Fractures.

Delma Stephanie, Ozdag Yagiz, Manzar Shahid, El Koussaify Jad, Foster Brian K, Akoon Anil, Dwyer C Liam, Klena Joel C, Grandizio Louis C

ОбзорСтатьяПеревод в очереди

Аннотация

PURPOSE: Occupational radiation exposure can have adverse health consequences for surgeons. The purpose of this study was to determine if utilization of an intraoperative, real-time radiograph counter results in decreased radiation exposure events (REEs) during open reduction and internal fixation (ORIF) of distal radius fractures (DRFs).

METHODS

We reviewed all cases of isolated ORIF DRFs performed at a single center from January 2021 to February 2023. All cases performed on or after January 1, 2022 used an intraoperative radiograph counter, referred to as a "shot-clock" (SC) group. Cases prior to this date were performed without a SC and served as a control group (NoSC group). Baseline demographics, fracture, and surgical characteristics were recorded. Final intraoperative radiographs were reviewed to record reduction parameters (radial inclination, volar tilt, and ulnar variance). REEs, fluoroscopy exposure times, and total radiation doses milligray (mGy) were compared between groups.

RESULTS

A total of 160 ORIF DRF cases were included in the NoSC group, and 135 were included in the SC group. The NoSC group had significantly more extra-articular fractures compared with the SC group. Reduction parameters after ORIF were similar between groups. The mean number of REEs decreased by 48% in the SC group. Cases performed with the SC group had significantly lower total radiation doses (0.8 vs 0.5 mGy) and radiation exposure times (41.9 vs 24.2 seconds). Mean operative times also decreased for the SC group (70 minutes) compared with that for the NoSC group (81 minutes).

CONCLUSIONS

A real-time intraoperative radiograph counter was associated with decreased REEs, exposure times, and total radiation doses during ORIF DRFs. Cases performed with a SC had significantly shorter operative times without compromising reduction quality. Using an intraoperative SC counter during cases requiring fluoroscopy may aid in decreasing radiation exposure, which serves as an occupational hazard for hand and upper-extremity surgeons.

TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic II.

Для цитирования: Delma Stephanie, Ozdag Yagiz, Manzar Shahid, El Koussaify Jad, Foster Brian K, Akoon Anil, Dwyer C Liam, Klena Joel C, Grandizio Louis C. The Effect of an Intraoperative Real-Time Counter on Radiation Exposure Events During Operative Treatment of Distal Radius Fractures.. The Journal of hand surgery. 2023. DOI: 10.1016/j.jhsa.2023.07.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.