MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ultrasmedbio.2020.06.022

Медицинская библиотека · Ultrasound in medicine & biology · 2020

Ultrasound Imaging of Injections in Masseter Muscle without Contrast Agent Using Strain Elastography and a Novel B-Mode Spatiotemporal Filter.

Sanabria Sergio J, Ruby Lisa, Kuonen Jasmine, Dettwiler Susanne, Colombo Vera, Frauenfelder Thomas, Ettlin Dominik, Rominger Marga B

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Botulinum toxin type A (BTX-A) injections in masseter muscle can alleviate muscle tightness and aching pain caused by idiopathic masticatory myalgia, a subform of the myofascial pain syndrome. Yet the injection procedure (number, amount) is currently empirical. In this ex vivo study, we determined the feasibility of using contrast-free ultrasound imaging to visualize the short-term injectate propagation. Ultrasound annotations of BTX-A injectate spread in N = 12 porcine masseter muscles were compared with the histopathology of the excised masseter. BTX-A presence was automatically detected in the ultrasound cine by: compensating tissue motion and deformation during injection with a novel spatiotemporal filtering (SF) algorithm, and by imaging tissue swelling strains with strain elastography (SE). BTX-A injectate introduced 6.5% (standard deviation = 5.0%) echogenicity contrast and 13.9% (standard deviation = 3.7%) tissue swelling strain. Muscle fasciae were a border for BTX-A distribution. The SF algorithm achieved significantly higher noise rejection (contrast-to-noise ratio = 4.63) than SE (2.56, p = 0.01), and state-of-the-art 2-D digital image correlation (1.81, p < 0.001) and direct image subtraction (1.29, p < 0.001) methods. Histopathology agreed well with ultrasound (Dice coefficient = 0.48), with deviations mainly explained by the three-dimensional inhomogeneous distribution of BTX-A. Preliminary in vivo patient results indicated that SF and SE discard artifactual BTX-A detection outside the injection region. The proposed methods contribute to objectivize ultrasound-guided injections, with additional applications, for instance, to monitor injectate spread of local anesthetics.

Для цитирования: Sanabria Sergio J, Ruby Lisa, Kuonen Jasmine, Dettwiler Susanne, Colombo Vera, Frauenfelder Thomas, Ettlin Dominik, Rominger Marga B. Ultrasound Imaging of Injections in Masseter Muscle without Contrast Agent Using Strain Elastography and a Novel B-Mode Spatiotemporal Filter.. Ultrasound in medicine & biology. 2020. DOI: 10.1016/j.ultrasmedbio.2020.06.022.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.