MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00590-023-03685-w

Медицинская библиотека · European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2023

Does the type of medial plate fixation matter for supplemental fixation of distal femur fractures manage with a lateral pre-contoured locked plate? A Biomechanical study.

Pereira Sebastián, Bidolegui Fernando, Garabano Germán, Pesciallo Cesar Angel, Giordano Vincenzo, Pires Robinson Estevez, Mariolani José Ricardo, Belangero William Dias

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Fixation of distal femur fractures with a lateral pre-contoured locking plate provides stable fixation and is the standard treatment in most cases, allowing early range of motion with a high rate of union. However, in situations, the stability achieved with the lateral plate alone may be insufficient, predisposing to fixation failure. The objective of the study was to compare, in synthetic bone models, the biomechanical behaviour of the fixation with a distal femur lateral pre-contoured locking plate solely and associated with a 3.5 mm proximal humeral locking plate applied upside down or a 4.5 mm helical locking compression plate on the medial side.

MATERIAL AND

METHODS

A total of 15 solid synthetic left femur samples were used. A metaphysical defect at the level of the medial cortex was simulated. The samples were randomly distributed into three groups equally. All groups received a 4.5/5.0 mm single lateral 9-hole distal femur lateral pre-contoured locking plate. Group 1 had no supplementary plate. Group 2 received a supplementary 6-hole 3.5 mm proximal humeral locking plate and Group 3 received a supplementary 4.5/5.0 mm helical 14-hole narrow locking compression plate.

RESULTS

Both supplementary plate types used in groups 2 and 3 contributed to increase the apparent stiffness of the construct, but pairwise comparison showed statically significant difference only between group 1 and 3. No significant difference was observed between groups 2 and 3.

CONCLUSION

Both supplementary plates might be considered for improving the fixation in distal femur fracture in selected cases.

Для цитирования: Pereira Sebastián, Bidolegui Fernando, Garabano Germán, Pesciallo Cesar Angel, Giordano Vincenzo, Pires Robinson Estevez, Mariolani José Ricardo, Belangero William Dias. Does the type of medial plate fixation matter for supplemental fixation of distal femur fractures manage with a lateral pre-contoured locked plate? A Biomechanical study.. European journal of orthopaedic surgery & traumatology : orthopedie traumatologie. 2023. DOI: 10.1007/s00590-023-03685-w.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.