MedElevator Войти в исследования
← Поиск публикаций

DOI 10.7547/1010424

Медицинская библиотека · Journal of the American Podiatric Medical Association · 2011

Evaluating intratester reliability of manual masking of plantar pressure measurements associated with chronic gout.

Rome Keith, Survepalli David George, Lobo Maria, Dalbeth Nicola, McQueen Fiona, McNair Peter J

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Plantar pressure measurements are commonly used to evaluate foot function in chronic musculoskeletal conditions. However, manually identifying anatomical landmarks is a source of measurement error and can produce unreliable data. The aim of this study was to evaluate intratester reliability associated with manual masking of plantar pressure measurements in patients with gout.

METHODS

Twenty-five patients with chronic gout (mean disease duration, 22 years) were recruited from rheumatology outpatient clinics. Patients were excluded if they were experiencing an acute gout flare at the time of assessment, had lower-limb amputation, or had diabetes mellitus. Manual masking of peak plantar pressures and pressure-time integrals under ten regions of the foot were undertaken on two occasions on the same day using an in-shoe pressure measurement system. Test-retest reliability was assessed by using intraclass correlation coefficients, SEM, 95% limits of agreement, and minimal detectable change.

RESULTS

Mean peak pressure intraclass correlation coefficients ranged from 0.92 to 0.97, with SEM of 8% to 14%. The 95% limits of agreement ranged from-150.3 to 133.5 kPa, and the minimal detectable change ranged from 30.8 to 80.6 kPa. For pressure-time integrals, intraclass correlation coefficients were 0.86 to 0.94, and SEM were 5% to 29%, with the greater errors observed under the toes. The 95% limits of agreement ranged from -48.5 to 48.8 kPa/sec, and the minimal detectable change ranged from 6.8 to 21.0 kPa/sec.

CONCLUSIONS

These findings provide clinicians with information confirming the errors associated with manual masking of plantar pressure measurements in patients with gout.

Для цитирования: Rome Keith, Survepalli David George, Lobo Maria, Dalbeth Nicola, McQueen Fiona, McNair Peter J. Evaluating intratester reliability of manual masking of plantar pressure measurements associated with chronic gout.. Journal of the American Podiatric Medical Association. 2011. DOI: 10.7547/1010424.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.