MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00068-024-02598-5

Медицинская библиотека · European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2024

Traditional radiography versus computed tomography to assess reduced distal radius fractures.

Dankelman Lente H M, Barvelink Britt, Verhofstad Michael H J, Wijffels Mathieu M E, Colaris Joost W

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

INTRODUCTION

This study compares computed tomography (CT) with plain radiography in its ability to assess distal radius fracture (DRF) malalignment after closed reduction and cast immobilization.

METHODS

Malalignment is defined as radiographic fracture alignment beyond threshold values according to the Dutch guideline encompassing angulation, inclination, positive ulnar variance and intra-articular step-off or gap. After identifying 96 patients with correct alignment on initial post-reduction radiographs, we re-assessed alignment on post-reduction CT scans.

RESULTS

Significant discrepancies were found between radiographs and CT scans in all measurement parameters. Notably, intra-articular step-off and gap variations on CT scans led to the reclassification of the majority of cases from correct alignment to malalignment. CT scans showed malalignment in 53% of cases, of which 73% underwent surgery.

CONCLUSION

When there is doubt about post-reduction alignment based on radiograph imaging, additional CT scanning often reveals malalignment, primarily due to intra-articular incongruency.

Для цитирования: Dankelman Lente H M, Barvelink Britt, Verhofstad Michael H J, Wijffels Mathieu M E, Colaris Joost W. Traditional radiography versus computed tomography to assess reduced distal radius fractures.. European journal of trauma and emergency surgery : official publication of the European Trauma Society. 2024. DOI: 10.1007/s00068-024-02598-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.