MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10278-024-01185-9

Медицинская библиотека · Journal of imaging informatics in medicine · 2024

Minimal Detectable Bone Fracture Gaps in CT Images and Digital Three-Dimensional (3D) Radii Models.

Bittner-Frank Martin, Strassl Andreas, Unger Ewald, Hirtler Lena, Eckhart Barbara, Koenigshofer Markus, Stoegner Alexander, Staats Kevin, Kainberger Franz, Windhager Reinhard, Moscato Francesco, Benca Emir

СтатьяПеревод в очереди

Аннотация

Knowledge of the minimal detectable bone fracture gap is essential in three-dimensional (3D) models, particularly in pre-operative planning of osteosynthesis to avoid overlooking gaps. In this study, defined incisions and bony displacements ranging from 100 to 400 µm were created in diaphyseal radii in 20 paired forearm specimens and verified with light microscopy. The specimens were scanned utilizing different computed tomography (CT) technologies/scanners, specimen positionings, scan protocols, image segmentations, and processing protocols. Inter- and intra-operator variabilities were reported as coefficient kappa. In CT images, fracture gaps of 100 µm and bone lamellae of 300 µm and 400 µm width were identified at a rate of 80 to 100%, respectively, independent of the investigated settings. In contrast, only 400µm incisions and bony displacements were visible in digital 3D models, with detection rates dependent on CT technology, image segmentation, and post-processing algorithm. 3D bone models based on state-of-the-art CT imaging can reliably visualize clinically relevant bone fracture gap sizes. However, verification of fractures to be surgically addressed should be verified with the original CT image series.

Для цитирования: Bittner-Frank Martin, Strassl Andreas, Unger Ewald, Hirtler Lena, Eckhart Barbara, Koenigshofer Markus, Stoegner Alexander, Staats Kevin, Kainberger Franz, Windhager Reinhard, Moscato Francesco, Benca Emir. Minimal Detectable Bone Fracture Gaps in CT Images and Digital Three-Dimensional (3D) Radii Models.. Journal of imaging informatics in medicine. 2024. DOI: 10.1007/s10278-024-01185-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.