MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/230949901402200315

Медицинская библиотека · Journal of orthopaedic surgery (Hong Kong) · 2014

Total hip replacement using a highly crosslinked polyethylene liner in Asians with small acetabulum.

Chua Weiliang, Roy Shuvendu, Sng Jonathan, Liang Shen, De Shamal Das

СтатьяПеревод в очереди

Аннотация

PURPOSE: To evaluate the medium-term outcomes of total hip replacement (THR) using a thin highly cross-linked polyethylene (HXLPE) liner in an Asian population.

METHODS

Medical records of 20 men and 44 women aged 26 to 80 (mean, 59) years who underwent 80 THRs using a thin HXLPE liner by a single surgeon were reviewed. Indications for THR included dysplasia (n = 26), avascular necrosis (n=26), osteoarthritis (n = 22), rheumatoid arthritis (n = 4), and ankylosing spondylitis (n = 2). The surgical technique, implant used, and rehabilitation protocol were standardised. Radiographs were evaluated for cup migration and peri-implant radiolucency. Femoral head penetration was assessed at day 1 and last follow-up using the Kang modification of the Dorr and Wan method and the PowerPoint method.

RESULTS

After a mean follow-up of 7.5 (range, 5.0-11.9) years, no patient had undergone acetabular revision. Two hips were revised for the femoral stem. Femoral head penetration did not correlate with sex, age at surgery, hip pathology, acetabular inclination angle, cup size, or liner thickness. The maximum femoral head penetration was 0.09 mm/year, which was below the osteolysis threshold of 0.1 mm/year. The mean ± standard deviation femoral head penetration was 0.29 ± 0.12 mm (or 0.04 ± 0.02 mm/year) by the PowerPoint method and 0.17 ± 0.22 mm (or 0.02 ± 0.03 mm/year) by the Kang modification of the Dorr and Wan method. Femoral head penetration correlated with the number of years of follow-up (p = 0.012).

CONCLUSION

The use of a thin HXLPE liner in primary THR for patients with small acetabulum achieved good outcomes after a mean of 7.5 years.

Для цитирования: Chua Weiliang, Roy Shuvendu, Sng Jonathan, Liang Shen, De Shamal Das. Total hip replacement using a highly crosslinked polyethylene liner in Asians with small acetabulum.. Journal of orthopaedic surgery (Hong Kong). 2014. DOI: 10.1177/230949901402200315.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.